INSTALLATION INSTRUCTIONS

EHP SERIES FILTER ELEMENTS

WARNINGS

DO NOT REPLACE ANY ITEM ON VESSEL WHILE IT IS UNDER PRESSURE.

DO NOT OPERATE LEAKING FILTER TAKE THEM OUT OF SERVICE IMMEDIATELY.

DO NOT OPERATE FILTER ABOVE MAXIMUM WORKING PRESSURE AND/OR MAXIMUM OPERATING TEMP.

USE THE PROPER SAFETY PRECAUTIONS FOR THE GAS BEING PROCESSED.



®

APRIL 2000

P/N: 432-10029

PRODUCT PURPOSE & FUNCTION:

Van Air's EHP series elements provide long service life as well as ease of maintenance. Both particulate and coalescing

elements will operate efficiently for extended periods of time until a pressure drop of 10 PSID has occurred. The activated carbon
element (RD grade) must be changed to suit specific applications, or at least every 6 months.

FILTRATION GRADES

APPLICATION

ELEMENT

GRADE

PURPOSE

NOMINAL

PARTICULATE

REMOVAL

MAXIMUM

INLET

TEMP. (°F)

ELEMENT

FLOW

DIRECTION

Oil Removal (Liquids)

AA

Extra Coarse

Coalescing

25.00µ

225

IN/OUT

A

Coarse
Coalescing

5.00µ

225

IN/OUT

B

General Purpose
Coalescing

1.00µ

175

IN/OUT

C

High Efficiency
Coalescing

0.01µ

125

IN/OUT

Solid Particulate

Removal

RAA

Extra Coarse
Particulate

25.00µ

225

OUT/IN

RA

Coarse Particulate

5.00µ

225

OUT/IN

RB

General Purpose

Particulate

1.00µ

225

OUT/IN

RC

High Efficiency
Particulate

0.01µ

225

OUT/IN

Oil Vapor Removal

RD

Vapor Adsorbing

0.01µ

80

OUT/IN

FLOW DIRECTION THROUGH ELEMENT

INLET

OUTLET

(COALESCING)

IN/OUT

(PARTICULATE)

OUT/IN

INLET

OUTLET

STAINLESS
STEEL OUTER
CORE (VISIBLE
ONLY ON RD
GRADE
ELEMENTS)

THREADED

TOP

ENDCAP

EHP-35, EHP-70/75,

EHP-100/110 &

EHP-175/195

EHP-6, EHP-15/20

& EHP-50

STAINLESS

STEEL

ENDCAP S

EHP-275 & EHP-550

CHEMICAL

RESISTANT

POLYESTER

OUTER SOCK

STAINLESS

STEEL

ENDCAPS

Advertising