Van Air Systems Autodrain Kit User Manual

Page 2

Advertising
background image

FIGURE 1 INSTALLATION DETAILS

THREAD FLATS

CONNECTION (1/8" NPT)

HEX NUT

1.
2.
3.

Place o-ring onto ADM-2-2.
Thread the ADM-2-2 into the drain hole of the filter bowl and tighten firmly by
hand.
Thread the 1/4" hex nut onto the outlet of the ADM-2-2 and tighten down with a 7/
16" wrench on the thread flats and 5/8" wrench on the hex nut.

INSTALLATION (Reference Figure 1)

WARNINGS

DO NOT INSTALL ADM-2-2 TO EQUIPMENT WHILE UNDER PRESSURE.
FOLLOW INSTRUCTIONS FOR ADM-2-2 WHEN INSTALLING INTO AIR
SYSTEM.
DO NOT OPERATE UNIT ABOVE 250 PSIG.

O-RING

FILTER BOWL

ADM-2-2