Van Air Systems EDV-115-PA User Manual

Terminator, Model edv-115-pa, Installation, operation & maintenance instructions

Advertising
background image

PAGE 1

JAN 2011

P/N 432-10045

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

TERMINATOR

ELECTRONIC DRAIN VALVE

Model EDV-115-PA

(1/2" VALVE, LARGE ORIFICE)

PRODUCT PURPOSE & FUNCTION:

Van Air's model EDV-115-PA series drain valve is designed to remove accumulated fl uids from compressed air & gas process-

ing equipment. With variable open time (1-60 seconds) and valve closed time (1-60 minutes), users can easily adjust the valve to drain
the required amount of accumulated fl uids. Power on and valve open status lights, as well as a built-in override/test function, give quick
verifi cation of valve operation.

TM

EDV

-115-P

A

TM

Lake Cit

y, P

A 16423 USA

Ph: (800) 840-9906

ww

w.vanairsy

stems

.com

POWER

ON

CLOSED TIME

MINUTES

10

60

50

40

30

20

TEST

VA

LVE

OPEN

OPEN TIME

SEC

ONDS

10

60

50

40

30

20

1

EDV-115-PA

TM

Lake City, PA 16423 USA

Ph: (800) 840-9906

www.vanairsystems.com

CLOSED TIME

MINUTES

TEST

VALVE
OPEN

OPEN TIME

SECONDS

10

60

50

40

30

20

1

POWER

ON

10

60

50

40

30

20

Van Air

Part No

39-10510

Valve In/Out

Port Size

1/2"NPT

Orifi ce

Size

7/16"

Ambient

Temp Range

(°F/°C)

32-150/0-66

Electrical

V/PH/HZ

115-1-50/60

C

v

2.75

Working

Pressure Range

(psig/bar)

3-300/.2-20.7

Maximum

Fluid Temp

(°F/°C)

210/99

Approx

Weight

(lbs/Kg)

1.6/.7

2-1/4"

2"

3-1/16"

3-1/2"

1-15/16"

3-11/16"

Amps

.09

FIGURE 1 SPECIFICATIONS

2-1/4"

4-13/16"

5-7/16"

EDV-115-PA

• READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS DRAIN VALVE.

• DO NOT OPERATE LEAKING OR DAMAGED VALVES. REMOVE THEM FROM SERVICE IMMEDIATELY.

• DO NOT OPERATE VALVE ABOVE MAXIMUM OPERATING PRESSURE AND/OR MAXIMUM TEMPERATURE.

• MAKE SURE NEMA RATING OF VALVE IS COMPATIBLE WITH THE INSTALLATION ENVIRONMENT. FAILURE TO DO
SO MAY RESULT IN SERIOUS PERSONAL INJURY AND/OR DAMAGE TO THE UNIT.

• WHEN INSTALLING THIS UNIT, COMPLY WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL CODES.

• DRAIN SOLUTION MAY CONTAIN LUBRICANTS AND/OR HAZARDOUS MATERIALS. BE SURE TO COMPLY WITH
ALL APPLICABLE REGULATIONS CONCERNING THEIR DISPOSAL.

• NOT FOR USE ON SINGLE TOWER (DELIQUESCENT) DRYERS OR WITH CORROSIVE LIQUIDS.

WARNING

2950 Mechanic Street

Lake City, PA 16423 USA

Phone: 800/840-9906

Fax: 814/774-3482

www.vanairsystems.com

Advertising