23

Rite Tensioning Device®

Caution:
The Rite Tension ® blade tensioner device has
been factory calibrated for your saw.
When re-tightening or replacing a blade, the 'T'
handle must be turned counter-clockwise at least
six turns to reset the Rite Tension ® mechanism.

1

150075

Blade Tensioning Ass'y
(includes items 2 thru 17 & 27)

2

101184

Take Up Screw Handle

3

100053-005 Roll Pin, 3/16 x 1

4

100030-007 Flat Washer, 1/2

5 100410-001

Thrust

Bearing

6 150068 Bearing

Housing

7 100116-007

Belleville Washer (2 req'd)

8

150074 Take Up Screw (includes items 2 & 9)

9

100052-026 Dowel Pin, 3/16 x 11/16

10 150069 Turn

Counter

11

100136-006 Spring, Large Diameter

12

100136-001 Spring, Small Diameter

13

100000-010 Machine Screw, 8-32 x 5/16 (2 req'd)

14 150067 Blade Tension Housing
15

100034-008 Set Screw, 1/4-20 x 1/4

16 150070 Tension

Adjuster

17 155068 Swivel

Nut

18 098030-004

Collar,

w/set

screw

19

100008-072 Cap Screw, HH 5/16-18 x 3/8 (2 req'd)

20

100004-013 Cap Screw, HH 5/16-18 x 5/8 (4 req'd)

21

100025-002 Lock Washer, 5/16 (4 req'd)

22

B-046

Slide Block Guide, (2 req'd)

23 101164

Slide

Block

24

B-010

Wheel Adjusting Block

25

100004-019 Cap Screw, HH 5/16-18 x 1-1/8 (4 req'd)

26 102360

Spacer

(4

req'd)

27 150190

Tensioner

Support