Up to 30 minutes in cooling time may be required depending on ambient temperature and operation being performed.

OVER CURRENT PROTECTION

Should the battery be overloaded and the maximum current draw be exceeded, the battery will temporarily stop
working to protect the internal components. The battery will resume to normal operation once the excessive current
draw has returned to normal safe level. This may take a few seconds.

SHORT CIRCUIT PROTECTION

If the battery pack was to short circuit the short circuit protector would immediately stop the battery pack from
operating.

This will ensure that no further internal components of the battery or the tool is damaged.

INSTALLING AND REMOVING THE BATTERY PACK FROM THE TOOL

TO INSTALL BATTERY PACK:

Insert battery pack into tool, until an audible click is heard.

TO REMOVE BATTERY PACK:

Depress the battery release button and pull battery pack out of tool.

TRIGGER SWITCH & REVERSING BUTTON

The drill is turned ON and OFF by pulling and releasing the trigger switch
(1). The farther the trigger is depressed, the higher the speed of the
screwdriver.

A forward/reverse control button (2) determines the direction of the tool
and also serves as a lock off button.

To select forward rotation, release the trigger switch and depress the
forward/reverse control button to the left.

To select reverse, depress the forward/reverse control button the opposite
direction.

NOTE: The center position of the control button locks the tool in the off
position. When changing the position of the control button, be sure the trigger is released.

ELECTRIC BRAKE

To stop the screwriver, release the trigger switch and allow the tool to come to a complete stop.
The electric brake quickly stops rotating. This feature engages automatically when you release the trigger switch.

LED WORKLIGHT

The LED worklight, located on the front of the tool, will illuminate when the trigger switch is depressed. This
provides additional light on the surface of the workpiece for operation in lower-light areas.

The LED worklight will turn off when the trigger switch is released.

 