Maintenance – WycoTool EH035 EZ-Vibe User Manual

Page 4

Advertising
background image

a) Starting Procedure

- Always check for gas tank and fuel hose leaks before using engine.
- Insure fresh fuel is in tank.
- Insure crank case is properly filled with oil.
- Insure switch is “On”.
- Push primer 7 to 10 times.
- If engine is cold, place choke to the closed position.
- Pull starter rope quickly, but do not pull to the point where additional

rope does not come out.

- If engine pops without starting, set choke to ½ open and pull again.

b) Vibrator Insertion

Insert vibrator vertically, allowing it to penetrate rapidly to the bottom
of the lift at least 6 inches into any previous lift. Hold the vibrator at the
bottom of the lift for 5 to 15 seconds. Pull vibrator up at a rate of about
5 seconds per foot. Insure that the radius of actions overlap (distance
between vibrators 1.5 times the radius of action)

4. MAINTENANCE

a) Vibrator Head

Maintenance on the head should be done after every 50 hours of use.
When servicing, automatically replace hex driver, seals, and bearings.

1) Hold the nose end in a vise and unscrew the end cap (counter-

clockwise) with a chain wrench or a good pipe wrench.

(See drawing on Page 7)

-3-

Advertising