Multifunction Temperature Calibrator

Additel 221A

Sourcing, simulating and measuring temperature

and electrical signals
Smartphone-like menu and interface make the

operation simple and simple
The internal cold junction compensation sensor

can be re-calibrated at ice point by users
Ultra-compact, 3.9" x 7.6" x 2.0", and 1.6 lb (0.7kg)

OVERVIEW

A highly integrated Multifunction Temperature Calibrator featuring several patented technologies. The 221A is an ultra-

compact, rugged, and easy to use hand-held device for sourcing, simulating and measuring temperature, and electrical

signals. Its smartphone-like menu and interface make the operation simple. The 221A is ideal for calibrating, maintaining,

and troubleshooting process instrumentation. Automation and documentation capabilities make the 221A a turnkey

solution.

Sourcing, simulating and measuring temperature
and electrical signals
Sources and measures mV, mA, ohms, RTDs,

thermocouples, frequency, and pulses

Simulates and measures 13 thermocouples and 11

RTDs to calibrate transmitters

24V loop power supply

Simultaneous dual reading capability

Automatic switch test

Supports square root transmitter

Pulse frequency output for the calibration of flow

totalizer

Easy to use
Smartphone-like menu and interface make the

operation simpler and easier

Ultra-compact, size 3.9" x 7.6" x 2.0" (100mm x 192mm

x 52mm), and weight 1.6 lb (0.7 kg)

One hand operation

Calibrated cold junction compensation (Patented)
Cold junction equivalent block in the calibrator

A calibrated PRT element with flexible leads is installed

in the equivalent block for thermocouple cold junction

compensation

This PRT element can be pulled out from the calibrator

and re-calibrated and corrected at ice point by users

Built-in temperature readout
CVD coefficients of a calibrated PRT can be input into

the calibrator for accurate temperature measurement.

Multi lingual interface
English, German, French, Italian, Spanish, Portuguese,

Simplified Chinese

(Traditional Chinese, Japanese and Russian are

available per request)

Documenting and automated procedure capability
Manage the information of the device under test.

Set up automated calibration procedures, and

ADT221A performs the test, calculates the errors,

displays and/or stores the results in the memory, and

highlights the out-of-tolerance points.

As-found and As-left functions allow recording and

documenting results for quality control.

Download tasks and upload the results.

Snapshots allow you to capture and save work.

Build-in unit conversion tool
Build-in converters for pressure units, temperature

units, temperature vs. resistance (RTDs), and

temperature vs millivolt (thermocouples)

Display
3.5 inch TFT color screen

Rugged
Rugged design for harsh environments.

Passed a 1-meter drop test.

Three years warranty for the ADT221A, and one year

for the battery pack

Misuse protection
Up to 30V voltage on any two sockets and up to

1A current on current sockets will not damage the

calibrator. The calibrator will return to normal condition

as soon as the voltage or current is removed.

NIST Traceable Calibration with data
Rechargeable battery
Rechargeable Li-ion battery for 15 hours uninterrupted

use.

Battery life will be reduced when 24V is applied.

The rechargeable battery is replaceable.

Warranty: 3 years