Aquametrix P/R60C-4 Differential pH or ORP Probes User Manual

Aquametrix, Water analytics, Description

Advertising
background image

Differential Measurement

Replaceable Salt Bridge

Low Maintenance Cost

Field-proven

Easy Cleaning

Semi-flush face: re-

duced buildup
Encapsulated Preamp

Transmits up to 3000 ft.

Options

4-20 mA two-wire blind-

transmitter version available

ORP available with

gold electrode

Aquametrix Model P/R60C-4

Differential pH or ORP Probes

100 School Street

Andover, MA 01810

978-749-9949

Toll free - 855-747-7623

www.WaterAnalytics.net

Process Control

Industrial and Municipal Wa-

ter Treatment

Industrial and Municipal

Waste Treatment and Neutral-

ization

Fume Scrubbers, Plating,

Circuit Board Manufacturing,

Food and Beverage, Chemi-

cal Processing, Pulp and Pa-

per, Mining, Power Generation,

Pharmaceutical Industry

Description

www.WaterAnalytics.net

978-749-9949

888-749-9099

Features

Applications

The P60C-4 pH and the R60C-4 ORP probe are dependable indus-

trial grade sensors designed to provide accurate measurement and

longer service life under the most demanding conditions.
Some features of these probes include: differential measurement

technology, replaceable salt bridge and encapsulated preamp.
The P/R60C-4 incorporates all the benefits of differential measure-

ment found in other models of the 60 series, field proven in thou-

sands of installations. This technique uses two glass electrodes to

make the measurement differentially with respect to a third metal

electrode. The domed glass process electrode is specially designed

for tough applications. The second electrode is immersed in a pH 7

buffer encapsulated in the probe. This second electrode is protected

from the process by a double junction replaceable salt bridge. The

resulting true differential measurement has several advantages over

conventional probes: ground loop problems are virtually eliminated,

and the salt bridge is easily replaced.
If the internal solution becomes contaminated, the probe can be re-

juvenated at modest cost by replacing the salt bridge and reference

solution. Automatic temperature compensation is accomplished

through the use of a thermistor at the tip of the probe. This thermistor

placement provides rapid response for process temperature varia-

tions.
The encapsulated preamplifier provides an output signal which can

be transmitted 3000 feet over inexpensive cable. Another version en-

capsulates a blind 4-20 mA two wire transmitter which can transmit

a virtually unlimited distance over a twisted pair cable. (See P/R65

data sheet).

by

Water Analytics

AquaMetrix

by

Water Analytics

AquaMetrix

Advertising