Ordering information pressure ranges, Pressure psi, Pressure code v ented – AST AST4600 Datasheet User Manual

Page 2: Pressure code factory sealed, Wiring

Advertising
background image

TM

www.astsensors.com

© 2014 American Sensor Technologies Inc. AST4600 01/30/2014.

All specifications subject to change without notice.

Ordering Information

Pressure Ranges

++

2.5 and 7.5 PSI units must be ordered in inches of H

2

O

Pressure PSI

0-1

Pressure Code V

ented

G

0001

Pressure PSI

0-100

Pressure Code Factory Sealed

0

0100

0-2.5

++

G

0069

0-200

0

0200

0-5

G

0005

0-500

0

0500

0-7.5

++

G

0208

0-1,000

0

1000

0-10

G

0010

0-1,500

0

1500

0-15

G

0015

0-2,500

0

2500

0-25

G

0025

0-3,000

0

3000

0-50

G

0050

0-5,000

0

5000

0-100

G

0100

0-7,500

0

7500

0-200

G

0200

0-10,000

1

0000

0-500

G

0500

0-15,000

1

5000

0-1,000

G

1000

0-20,000

2

0000

Output

Red

Black

White

Green

Voltage

+V Supply

-V Supply

Output

Case Ground

4-20mA

+V Supply

-V Supply

Not Used

Case Ground

For U.S. installations, sensor case ground (green wire) must be

bonded to ground according to Article 501 & 505 of the NEC.

Wiring

Options

000= No Options

Process Connection*

A= 1/4" NPT Male (up to 10,000 PSI)

I= 1/4" NPT Female (up to 15,000 PSI)

P= 1/2" NPT Male (up to 15,000 PSI)

W= F250C Female Autoclave (10,000 to 20,000 PSI)

* for other ports contact factory, "W" not available in 316L

Pressure Unit

B= Bar

K= kg/cm

2

P= PSI

Wetted Material

+

0= 17-4PH 1= 316L 2= Inconel 718 4= Hastelloy C276

+

Consult factory on availability of Inconel 718 and Hastelloy C276

Series Type

Insert Pressure Code

AST4600

A

0000

P

4

1

000

T

1

Pressure Range

G= Gauge Pressure**

V= Gauge Pressure (Vacuum Calibrated)**

0= Sealed Gauge up to 9,999 PSI

1= Sealed Gauge up 10,000 to 19,999 PSI

2= Sealed Gauge 20,000 PSI

** Not suitable for Class II

Electrical

T= 2ft. 18 AWG wires

U= 4ft. 18 AWG wires W= 2 Meter 18 AWG wires

Outputs

3= 1-5V 4= 4-20mA (2 wire loop powered) 6= 1-6V

-Z

Approval

-Z= Add “-Z” for CRN Registered to ANSI/ASME B31.3. Contact factory for material, pressure, and process connection options.

Advertising