Technical data – AW Gear Meters IF Series User Manual

Page 2

Advertising
background image

AW-Lake Company 8809 Industrial Drive, Franksville, WI 53126 Tel. 800-850-6110 Fax. 262-884-9810

Rev 1/2012

[email protected] www.awgearmeters.com Doc ID: IF Series w/ VTEG Amp.Ind

Version
2-Wire
3-Wire active NPN
3-Wire active PNP
3-Wire passive NPN

J3
Off
On
On
Off

J5
Off
Off
On
Off

J6
Off
On
Off
On

Terminal
1, 2
1, 2, 3
1, 2, 3
1, 2, 3

J4
On
Off
Off
Off

Jumper Setting and Terminals

Technical Data

Operating temp:

-20°C to + 80°C

Supply voltage:

U

B

: 7 to 29V/DC

Current consumption: I

R

< 4mA

Output:

Square wave frequency output

Electrical data:

Voltage level NPN/PNP (three-wire connection)

Current level (two-wire connection)

High level: I

High

> 2.2mA

Low level: I

low

< 1.4mA

A) Active output NPN

High level: U

High

> U

B

- 0.6V - (2.6k x I

out

)

Low level: U

Low

> 0.6V + (1.3k x I

out

)

C) Active output PNP

High level: U

High

> U

B

- 0.6V - (150 x I

out

)

Low level: U

Low

= cut off

D) Passive output PNP (OC-output)

High level: U

High

> U

B

- 0.6V - (150 x I

out

)

Low level: U

Low

= cut off

U

B

is the applied voltage at the output. 29V max.

I

max

= 60mA; P

max

on R

s

= 1W; R

s

= 150

Input impedance:

< 100

Input:

0.5mV up to 0.5V

Frequency range:

7-3000 Hz according to flowmeter type

Electrical connection:

Terminals 1, 2, 3 for supply voltage, ground & signal outlet

Terminals 4, 5, 6 for shield and inductive pickup

B) Passive output NPN (OC-output)

High level: U

High

= U

B

Low level: U

Low

< 0.6V + (1.3k x I

out

)

U

B

is the applied voltage at the output. 29V max.

VIEG Amplifier

VIEG Amplifier

Housing:

Aluminium

IP65 (DIN40050)

L = 64mm; W = 58mm; H = 37mm

two cable glands PG7, plastic

Advertising