Quad-4 dual hall effect pickup module, Installation and technical data guide, Rev 07/09 – AW Gear Meters Quad-4 User Manual

Page 2: Technical data

Advertising
background image

Quad-4 Dual Hall Effect Pickup Module

Installation and Technical Data Guide

AW Flow Meters - Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810

Email: [email protected] www.awcompany.com

Rev 07/09

Sinking Output Circuit

~40 Ohm

SUPPLY

OUTPUT

GROUND

Analog
Switch

Sourcing Output Circuit - Default from Factory

~40 Ohm

SUPPLY

OUTPUT

GROUND

Analog
Switch

• Output selection jumper off: remove shorting block from

JP1 & JP2

• User may need to add external components to interface

to displays or other instruments

• User must limit output voltage to Supply -1V
• Max current sinking capability: 50mA

• Output selection jumper on: place shorting block across

JP1 & JP2

• Signal output square wave :

Vhigh = Supply -1V @ no output load
Vlow = 0.1V

• Max sourced output voltage: Supply -0.5V
• Max current sourcing capabilities: 50mA

Supply Voltage:

+10 to 27 Volt DC

Supply Current:

75 mA @ 24 VDC

Duty Signal:

50% ± 15%

Minimum Signal:

0.5 Hz

Maximum Signal:

1,000 Hz

Frequency Output:

Flow dependent, up to 2,000 Hz

Driving Capacity:

50 mA Max resistive load

Output Impedance:

~ 40 Ohm - analog switch and self-resetting fuse

Temperature Range:

-40° F to 185° F (-40° C to 85° C)

Technical Data: