Doric Instruments 1000 Pro Series Digital Panel meters are suitable User Manual

Page 12

Advertising
background image

11

1000-XDCA High Dc Current

The 1000-XDCA high Dc shunt meter accepts an input from
60,100 and 150 Vdc current shunts and scales the reading to the
desired full scale reading of between 50.0 and 2000 amps. Ranges
are selected by a combination of jumpers located on the main board
(see page 6). No other adjustments are necessary. Use the table on
the following page to configure the meter.

The following ranges can be selected as full scale:
50 amps

1000 amps

100 amps

1500 amps

200 amps

2000 amps

500 amps

Example 1. Configure the meter to display 500 amps Dc
full scale with a 100mVDc input. Install jumpers provided on
position 3.

Example 2. Configure the meter to display 1999 amps Dc full
scale with 60mVDc input. Install jumpers provided on positions
6,7,8 and 9.

Advertising