Installation, Warning – Edwards Signaling 125XBRi Chameleon User Manual

Page 2

Advertising
background image

P/N 3101611 ISSUE 3

Installation

- Applications with a separate PLC or Controller - Set

dipswitches SW1 and SW2 to the OFF position.

Table 2. PLC Compatibility

GRAY BASE

BLACK BASE

Catalog Number

Catalog Number

Operating

Voltage (Volts)

Max. off state leak-

age current (mA)

Continuous on

current (mA)

Surge (inrush/duration)

(A/μSeconds)

125XBRiRGA24D

125XBRiRGA24DB

24V DC

5

150

28.5/65

125XBRiRBA24D

125XBRiRBA24DB

125XBRiRGA120A

125XBRiRGA120AB

120V AC 50/60 Hz

5

100

28.5/212

125XBRiRBA120A

125XBRiRBA120B

To avoid risk of injury, install lens before

energizing the unit and do not remove or

insert light source when unit is energized.

WARNING

1. Remove (4) screws securing the lens to the base from

bottom of base (Figure 2) and remove lens.
- Applications without a separate PLC or Controller

- XTRA-SAFE Technology Disabled: Set dipswitch

SW1 to the OFF position and SW2 to the ON

position.

WARNING

To prevent electrical shock, ensure that power

is turned off before installing the signal.

The 125XBRi Multi-Status indicator is shipped with XTRA-

SAFE Technology Enabled. The unit offers two other field

selectable options: (1) for applications without a separate

PLC or controller with the XTRA-SAFE Technology disabled

or (2) for applications with a separate PLC or controller. For

more information on the features, refer to the description.

For settings, refer to Figure 1.

XTRA-SAFE Enabled

XTRA-SAFE Disabled

With a PLC or other External Controller

2. Replace lens on base and secure with (4) screws

removed in step 1.

Figure 1. Dipswitch Settings

Applications WITH
a PLC or Controller*

Applications WITHOUT
a PLC or Controller* -
XTRA-SAFE Technology
Disabled

Applications WITHOUT
a PLC or Controller* -
XTRA-SAFE Technology
Enabled
(Factory Default)

*It is generally recommended that both dipswitches, SW1 and SW2,

be set to OFF for applications using an external Programmable Logic

Controller (PLC) or other external controller. A PLC or controller, how-

ever, can be used with any of the shown configurations.

Lens

O-Ring (in groove)

(supplied)

Base

(4) Screws securiing

lens to base

Figure 2. Removing the Lens

Advertising