Ge security industrial, Ordering information/electrical specifications, General specifications – Edwards Signaling 383 User Manual

Page 2: Mounting configurations, Accessories

Advertising
background image

www.ge-security.com/industrial

12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 800-247-9447
Fax: 503-691-7563

GE Security
Industrial

©2004 GE Security Industrial. GE Security Industrial reserves the right to change specifications without notice.
I-3898-0204 11511 Rev

C

Ordering Information/Electrical Specifications

PART NUMBER

1

CONTACT

2

LOAD RATING

SWITCHING VOLTAGE

SWITCHING CURRENT

CONTACT

NOMINAL SENSE RANGE

3

BREAK RANGE

TERMINAL

CONFIG.

AC/DC

MAXIMUM, AC/DC

MAXIMUM, AC/DC

RESISTANCE

Max. Min.

NOMINAL

TYPE

381-CT

N.O.

2.5VA/2.5W

[email protected] [email protected]

[email protected] [email protected]

0.5 Ohms

0.75"(1.9cm) 0.375"(1.0cm)

1.2"(3.0cm)

#6 Screw

381-DT

5

N.O.

150VA/NA

[email protected] NA

1.25A

4

@120V NA

NA

0.75"(1.9cm) 0.375"(1.0cm)

1.2"(3.0cm)

#6 Screw

Warning— Each electrical rating is an individual maximum and cannot be exceeded!

1

The part numbers 381 and 383 are the same in all respects except the conduit connection, 381 is left and 383 is right.

2

Configuration with actuator away from the switch

3

Proximity of ferrous materials usually reduces sense range — typically by 50%. The shape and type of material cause a wide diversity of effects.
Testing is required to determine actual sense range for specific applications.

4

Can withstand inrush surge up to 4 amps. Voltage drop is 1.5V. Minimum Switch Current 30mA.

5

Do not exceed 10 switches in series.

General Specifications

Enclosure

Coated Aluminum

Temperature Range

-40

°

F to 180

°

F (-40

°

C to 80

°

C)

Environmental

Hermetically Sealed Contact Switch

Encapsulated in Polyurethane

NEMA Rating

1, 2, 5

Protection Class

IP 64

Response Time

1 msec (5.4VA); 10 msec (150VA)

Life Cycles

100,000 Under Full Load;

Up to 200,000,000 Under Dry Circuit

Conduit Connection

1/2" Threaded NPT

UL/CSA

All Models

Perpendicular

Actuation

Door

Actuation

Parallel Actuation

Best

Best

Not Recommended

Pivot Actuation

Good

Figure 2

Mounting Configurations

The parallel actuation can result in on/off/on signal if the actuator passes by the
switch rather than coming to rest in proximity to it. This is NOT a recommended
configuration for safety interlock applications.

LR89176

Accessories

PART NUMBER

TAMPER PROOF SCREWS & SCREWDRIVER

1953

#6 x 3/4"L Tampruf

Roundhead Screw

1954

#8 x 1-1/2"L Tampruf Roundhead Screw

1955

Tampruf

®

Screwdriver

1956

Tampruf

®

1/4" Drive Bit for #6 and #8 Screws

4. For best protection against operator defeat, mount with non-removable screws,

bolts or nuts (see Accessories).

5. When mounting a metal switch to an ungrounded machine, connect the ground lead

to one of the switch mounting screws.

triac