Figure 1. Conduit Mounting (3/4" Shown)

Figure 2. Panel Mounting

P/N 3100414 ISSUE 1

Table 1. PLC Compatibility

Operating

Max. off state

Continuous

Surge

voltage

leakage current

on current

(inrush/duration)

Cat. No.

Volts

mA

mA

A/mSeconds**

103-RBA-G1

24V DC

5

65

0.070/8

103-RGA-G1
103-RBA-N5

120V AC

5

55

0.100/8

103-RGA-N5
*All AC volts at 60 Hz

** Amps/milliseconds

103I Series Chameleon
Visual Status Indicator

3/4" (19 mm) NPT
conduit (not supplied)

Power source wires

Wire Nuts
(not supplied)

Amber (DC hot or AC hot
for Amber LED activation)

Red (DC hot or AC hot
for Red LED activation)

Black (DC common) or White (AC neutral)

Blue or White with Green tracer

(DC hot or AC hot

for Blue or Green LED activation

(depending on model))

103I Series Chameleon
Visual Status Indicator

Gasket
(supplied)

Wire nuts

(not supplied)

Locking Nut -

1.3625" OD

(supplied)

Control panel

Amber (DC hot or AC hot
for Amber LED activation)

Red (DC hot or AC hot
for Red LED activation)

Black (DC common) or
White (AC neutral)

Blue or White with Green
Stripe (DC hot or AC hot
for Blue or Green LED activation
(depending on model))