Description

The Edwards 114 Series Beacons are UL and cUL listed signaling appli-
ances in a NEMA 4X and IP65 rated enclosure. They are available in either
steady-on or flashing incandescent. Separate models are available for sur-
face and pipe mounting. A protective wire guard, Cat. No. 114-GRD or a
180 degree dome block out assembly, Cat. No. 114-DBO are also available.

Specifications

Panel Mounting (Figure 2)

Note: The integrity of the outdoor, NEMA 4X, and IP65 rating on the
panel assembly at the interface with the 114 Series Visual Indicator relies
on the construction and configuration details of the mounting surface.
Installer should evaluate.

1.

Place the mounting gasket (supplied) over the hole in the panel and
route the signal wires through the gasket and the hole in the panel.

2.

Insert the base through the hole in the panel and screw the locking nut
(supplied), with the raised locking edge facing the mounting surface,
onto the base to secure the beacon.

3.

Using wire nuts (not supplied), connect the signal's wire leads as
shown in Figure 2. Polarity must be observed.

Catalog

Light

Replacement

Number

Voltage

Current

Mounting

Type

Bulb**

114SSIN*-G1

24V DC

0.61A

Surface

Steady-on

1692

114PSIN*-G1

24V DC

0.61A

1/2" Pipe

Steady-on

1692

114SSIN*-N5

120V AC

0.15A

Surface

Steady-on

15T7DC

114PSIN*-N5

120V AC

0.15A

1/2" Pipe

Steady-on

15T7DC

114SFIN*-G1

24V DC

0.61A

Surface

Flashing

1692

114PFIN*-G1

24V DC

0.61A

1/2" Pipe

Flashing

1692

114SFIN*-N5

120V AC

0.15A

Surface

Flashing

15T7DC

114PFIN*-N5

120V AC

0.15A

1/2" Pipe

Flashing

15T7DC

*Letter in this position indicates lens color: A - amber, B - blue, C - clear,
G - green, or R - red

**All bulb numbers listed are Industry Standard.

Installation

Conduit Mounting (Figure 1)

1.

Thread the 12" (45.7 cm) signal wire leads through 1/2" (13mm)
conduit into an approved conduit outlet box.

2.

Thread the conduit onto the base of the signal.

3.

Using wire nuts (not supplied), connect the signal's wire leads as
shown in Figure 1. Polarity must be observed.

CHESHIRE, CT 203-699-3000 CUST. SERV. FAX 203-699-3365 TECH. SERV. FAX 203-699-3078

WARNING

To prevent electrical shock, ensure that power is turned
off before installing the signal or performing any
maintenance.

Figure 1. Conduit Mounting

Maintenance

Figure 2. Panel Mounting

Cleaning

The module lens exterior surfaces should be periodically cleaned with a soft
clean cloth using water and a mild detergent to maintain optimum light
visibility. Disconnect power before cleaning.

Light Source Replacement

1.

Conduit Mounted Modules: Disconnect wiring and, if necessary,
unscrew base from conduit (Figure 1).

Panel Mounted Modules: Disconnect wiring and remove locking nut
securing the base to the panel (Figure 2).

2.

Remove screws securing the lens to the base from bottom of base and
remove lens.

3.

Unplug lamp and replace with new lamp as appropriate (see
specifications). Replace lens on base and secure with screws removed
in step 2.

WARNINGS

To prevent electrical shock, ensure that power is turned
off before installing the signal or performing any
maintenance.

To avoid risk of injury, install lens before energizing.

Table 1. Programming Logic Controller (PLC) Compatibility: PLC output to meet following product input parameters.

Operating voltage

Max. off state

Continuous on

Repetitive Surge

Cat. No.

(Volts)

leakage current (mA)

current (mA)

(Amps/milliseconds)

Surge (inrush/duration)

114SSIN-G1 or 114PSIN-G1

24V DC

25

25

0.68A

7A Exponentially decaying

114SSIN-N5 or 114PSIN-N5

120V AC

25

25

0.3A / 8 ms

0.8A Exponentially decaying

114SFIN-G1 or 114PFIN-G1

24V DC

25

25

2.5A / 60 ms

7A Exponentially decaying

114SFIN-N5 or 114PFIN-N5

120V AC

25

25

0.5A / 8 ms

0.8A Exponentially decaying

Gasket
(supplied)

Locking Nut -

1.3625" OD

(supplied)

Control panel

114 Series

Black
(DC common, AC hot)

Red (DC hot) or
White (AC neutral)

114 Series

1/2" (13 mm) NPT
conduit (not supplied)

Black
(DC common, AC hot)

Red (DC hot) or
White (AC neutral)

Advertising