GuardSwitch

Series 100

Installation

Use non-removable screws, bolts, or nuts to mount the switch and actuator. Do not
over-torque mounting hardware.

1. Using the following guidelines, determine a suitable mounting location:

• The switch and actuator must be within the listed sense range. See Ordering/

Electrical Specifications.

• The actuator must be aligned with the switch—labels facing the same direction.

(See Figure 1.)

Important: When mounting in proximity to ferrous material (steel), the sense
range can be reduced 50% minimum depending on the shape and type of
material. Test the switch in specific applications to determine the actual
sense range.

• When mounting on a ferrous material (steel), a 1/4" nonferrous (plastic or

aluminum) spacer may be used under the actuator and switch to restore most of
the lost gap.

0.75"

1.91cm

0.19"

0.48cm

115-3N-06K
115-3Y-06K
115-3Y-12K
115-4Y-06K
115-4Y-12K
115-6N-06K
115-6N-20K
115-6Y-06K
115-6Y-12K
115*-6Y-15K
115-6Y-18K-D6
115-6Y-20K
115*-6Y-25K
115-6Y-30K
115-6Y-30K-D6
115-7N-06K
115*-7X-25J
115-7Y-06K

115

Warning! To avoid switch failure determine the actual load of the switch circuit and
take steps to protect the switch from voltage spikes, current inrush and line/load
capacitance using the following recommendations.

• Surges from coils, motors, contactors, solenoids and tungsten filaments. Transient

protection, such as back-to-back zener diodes (Transorb) or an RC network, is
recommended for such loads to ensure that maximum ratings of the switch are
not exceeded.

• Line capacitance and load capacitance. An in-line resistor can be added in series

immediately before the load to limit the inrush current. The resistor can only be
added in series with the last wire just before the load. The voltage drop and the
power rating of the resistor must also be calculated as follows:

Voltage drop = I • R
Watts = I

2

• R

( I = maximum continuous current of the load)

To verify switch operation with an ohmmeter:

Set range at 20 mega ohms (switches with triac output, set ohm range at 20 kilo
ohms). For a normally open switch, the meter will read a high impedance with the
actuator away. It will read very high to infinity range (triac switches will read high kilo
ohm to infinity range) with the actuator within sense range. You will see the opposite
reading for a normally closed switch.

Interlock Switch

Dimensions

Figure 1

115-7Y-12K
115-7Y-25K
115-8Y-06K
115-8Y-06K-SER25
115-8Y-12K
115-8Y-12K-SER25
115-6Y-06K-D6
115-6Y-12K-D6
115-13Y-06K
115-13Y-12K
115-14Y-06K
115-14Y-12K
115-14Y-25K
115-17Y-06K
115-17Y-12K
115-EY-06K
115-__________