Edwards Signaling B-ERX-2100 User Manual

Description, Important telephone information, Electrical specifications

Advertising
background image

P-047550-1610 ISSUE 1

© 1995

FARMINGTON, CT 203-678-0410 FAX. 203-677-1621

Installation Instructions for Catalog Numbers B-ER-1000,

B-ER-2000, B-ERW-2100, B-ERX-2100 Electronic Telephone Relays

INSTALLATION

NOTE: Telecommunication wiring which is connected to

either the B-ER-1000 or B-ER-2000 relay shall not
extend outside the building that the relay module is
contained in.

Modular Indoor Unit (Figure 1)

NOTE: This device is for indoor use only with telephones

having modular (RJ11C type) jacks.

1.

Connect modular plug telephone line cord into modular jack
on bottom of electronic relay.

2.

Insert power cord of signal device to receptacle on side of
electronic relay.

3.

Plug unit into 120V, 60Hz wall outlet.

4.

Connect signaling devices to 120V outlet on relay. Verify
operability of electronic relay.

Hardwire Indoor Unit (Figure 2)

1.

Remove the four screws securing the relay housing cover
to the relay housing and remove the relay housing cover.

2.

Mount relay housing on flat surface using the 2 screws
provided.

3.

Wire as shown in Figure 4.

4.

Secure relay housing cover to relay housing using the four
screws removed in Step 1.

Weatherproof and Explosion Proof Units (Figure 3)

1.

Unscrew and remove the relay housing cover.

2.

Mount relay to selected surface using the cast ears. Carefully
orient the unit hubs with respect to the direction of incoming
and outgoing conduit wiring.

3.

Attach incoming and outgoing conduit to relay housing and
wire as shown in Figure 4.

4.

Screw relay housing cover back onto relay housing. Tighten
to sufficiently establish the gasketed integrity of the unit.

DESCRIPTION

The Edwards electronic telephone relays are available in four
models: Modular Indoor (Cat. No. B-ER-1000), Hardwire In-
door (Cat. No. B-ER-2000), Hardwire Weatherproof (Cat. No.
B-ERW-2100), Hardwire Explosion-Proof (Cat. No. B-ERX-
2100). The units are for use with horns, bells, strobes or similar
devices to create a remote signal extension that matches the tele-
phone ringing cycle. The relays are activated by ordinary ring-
ing voltage of the telephone.

• These devices are intended for connection to single line

telephone or key systems only. They are not intended for use
on "party line" or on coin telephone lines.

• When installed in accordance with these instructions, the

devices can be readily disconnected without affecting
equipment remaining on the telephone network.

• Registered with the Federal Communications Commission in

compliance with Part 68 of FCC Rules and Regulations.

• UL Listed.

IMPORTANT TELEPHONE INFORMATION

The following information may be required by the telephone com-
pany: Telephone Number, FCC Registration Number: 3Z9USA-
21250-RG-N.

The Ringer Equivalence Number (REN) allows the installer to
determine the number of devices that can be added to the tele-
phone line and still have all the devices ring when the number is
called. In most but not all areas, the sum of all RENs for all
devices connected to your line should not exceed five. To be
sure of the number of devices you can connect to your telephone
line, contact your local telephone company.

If these devices damage the telephone network, the telephone
company will notify the owner that it may temporarily discon-
nect service if they consider such action necessary. If the owner
considers the disconnection unwarranted, they have the right to
bring a complaint to the FCC.

The telephone company may make changes in its communica-
tion facilities, equipment, operations, or procedures when such
action is required. If these changes render the devices incompat-
ible with the telephone company facilities, the telephone com-
pany will provide enough written notice so that necessary changes
can be made in order to maintain uninterrupted service.

ELECTRICAL SPECIFICATIONS

Input

Max. Switching

Max Amps

Cat. No.

Description

Voltage

Voltage

Switch

REN

B-ER-1000

Modular

40-150 AC

120 AC

3.0

3.7B

Indoor

16-70 Hz

B-ER-2000

Hardwire

10-250 AC

120 AC

5.0

1.5B (>50V)

Indoor

16-70 Hz

3.4B (<50V)

10-150 DC

B-ERW-2100

Hardwire

10-250 AC

120 AC

5.0

1.5B (>50V)

Watertight

16-70 Hz

3.4B (<50V)

10-150 DC

B-ERX-2100

Hardwire

10-250 AC

120 AC

5.0

1.5B (>50V)

Explosion

16-70 Hz

3.4B (<50V)

Proof