110 cd model, Electronic strobes, Figure 3. v/i curves – Edwards Signaling CS405 User Manual

Page 2: 15/75 cd model

Advertising
background image

Figure 3. V/I Curves

110 cd Model

NOTE:

Use the average current rating to establish the maximum number of strobes, wire gauge and standby power requirements. Consult the
manufacturer to determine the peak current effects on the system.

910

900

890

870

828

220

210

200

190

235

370

363

357

330

385

150

250

350

450

550

650

750

850

950

20

21

22

23

24

Operating Voltage Full Wave Rectified

Operating Current (mA)

265

219

235

245

260

340

315

325

330

335

200

225

250

275

300

325

350

20

21

22

23

24

Operating Voltage DC

Operating Current (mA)

Iavg

Irms

Ipeak

Peak Inrush Current @ 24 Vdc = 7.8 A for

less than 50 microseconds.

Peak Inrush Current @ 24 Vdc = 6.8 A for

less than 50 microseconds.

GENERAL SIGNAL BUILDING SYSTEMS CORPORATION
SARASOTA , FL 941-739-4300 Fax. 941-753-1806
CHESHIRE, CT 203-699-3000 Fax. 203-699-3075

Figure 4. Strobe Light Output Distribution Patterns

UL Minimum
Requirement

Typical Output

90

O

90

O

-90

O

HORIZONTAL

VERTICAL

-90

O

0

25

50

75

100

125

150

175

- 90

- 75

- 60

- 45

- 30

- 15

0

15

30

45

60

75

90

Θ

(c d)

0

25

50

75

100

125

150

175

-90

-75

-60

-45

-30

-15

0

15

30

45

60

75

90

Θ

(c d)

0

25

50

75

100

125

150

Θ

110 cd

Model

Horizontal

Ceiling

Vertical

NOTE:

This equipment has been tested and found to comply with the limits for a

Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the
interference at his own expense.

CAUTION:

Changes or modifications to this equipment not expressly approved by

the party responsible for compliance could void the user’s authority to operate the
equipment.

Electronic strobes

CS405-7A-T

Electronic strobe, 15/75 cd red

CS405-8A-T

Electronic strobe, 110 cd red

530

526

524

522

520

98

94

92

90

102

186

181

177

172

190

50

150

250

350

450

550

20

21

22

23

24

Operating Voltage Full Wave Rectified

Operating Current (mA)

125

105

113

116

124

185

165

170

175

180

100

125

150

175

200

20

21

22

23

24

Operating Voltage DC

Operating Current (mA)

15/75 cd Model

Peak Inrush Current @ 24 Vdc = 7.6 A for

less than 50 microseconds.

Peak Inrush Current @ 24 Vdc = 6.8 A for

less than 50 microseconds.

0

20

40

60

80

Θ

15/75 cd

Model

0

10

20

30

40

50

60

70

80

-90

-75

-60

-45

-30

-15

0

15

30

45

60

75

90

Θ

(c d)

0

10

20

30

40

50

60

70

80

-90

-75

-60

-45

-30

-15

0

15

30

45

60

75

90

Θ

(c d)

P/N 387627 © 1996

OWEN SOUND, CANADA 519-376-2430 Fax. 519-376-7258
INTERNATIONAL: CANADA 905-270-1711 Fax. 905-270-9553

Advertising