USER MANUAL

Professional voltage detector HT20

4. Description

5. Operating instruction

Consider the herewith steps for a correct use of HT20:

1

Voltage detection sensor

2

Reference mark for CAT IV measurements

3

Hand safety protection

4 ON/OFF

key

5 Pen

clip

6

White LED torch

7

Fit part for battery cover sleigh

8

Battery cover sleigh

1. Safety precautions and procedures

Please follow the herewith indications before and during
the performance of any test with the instrument:

CAUTION

An improper use can damage the
instrument and/or its components or
injure the operator

Avoid using the instrument in rooms
where explosive gas, combustible gas,
steam or excessive dust are present

Do not perform any test if you notice
anomalous conditions such as
breakages, deformations, fractures,
leakages of battery liquid on meter

Do not perform any test exceeding the
declared voltage conditions

Do not perform measurements under
environmental conditions exceeding
the declared limits

Do not perform any voltage detection
with operator’s hand beyond the hand
safety protection

2. Introduction

HT20 meter can perform AC voltage detection with visible
LED red and acoustic buzzer indications. A white LED is
can be also activated by pressing ON/OFF key.

3. Features

 AC voltage detection with and without contact
 AC voltage detection on conductive and insulated parts
 Test on outlets, cables and/or electrical appliances
 Visible red LED and acoustic buzzer indications
 White torch LED with ON/OFF key
 Practical pen clip and very small size
 Auto

Power

OFF

 Meter suitable for any electrical installer

1. Perform a initial test with meter on a energized circuit.

Replace internal batteries if the red LED do not turn on
and/or the buzzer do not sound

2. Position the sensor close to or in contact with the point

under test then verify that the red LED is on and buzzer
sounds continuously as evidence of voltage detection.
Do not perform test with the operator’s hand
beyond the hand safety protection and position not
insulated wires beyond the CAT IV reference mark
(see part 2 of picture)

3. If necessary press ON/OFF key to turn on the white

LED torch

6. Batteries replacement

Follow the herewith steps to replace internal batteries:
1. Remove the meter from any voltage source
2. Perform a small pressure on battery cover sleigh (see

part 8 of picture)

3. Shift the battery cover sleigh from the meter
4. Replace the batteries with new ones of the same type

and pay attention to keep to correct polarity indication

5. Fit the battery cover sleigh to the meter
6. Used batteries must not be disposed of as urban waste

CAUTION: this symbol indicates that the
equipment and its accessories shall be subject
to a separate collection and correct disposal

7. Technical specifications

Voltage reference range: 100

 1000V AC to ground

Frequency reference range: 50/60Hz

Meter indications: visible LED and acoustic buzzer

Safety: IEC/EN61010-1

Category of measurement: CAT IV 1000V

Pollution degree: 2

Batteries: 2 x 1.5V alkaline type AAA IEC LR03

Working temperature: -10°C

 50°C (14°F  122°F)

Working humidity: -10

40°C;<75%HR;

40

 50°C <45%HR

Dimensions: 160(L)x26(W)x20(H)mm;6(L)x1(W)x1(H)”

Weight (included batteries): 48g (0.1lb)

Release EN 3.01 – 17/09/2012