Caution, O . l – HT instruments HT210 User Manual

Page 13

Advertising
background image

HT210

EN - 12

4.3.6. Capacitance

measurement

CAUTION

Before taking capacitance measurement in circuit remove power from the
circuit being tested and discharge all capacitors. Connect the test capacitor
to the inputs respecting the polarity connections when required.

Fig. 7: Using the instrument for capacitance measurement

1. Switch on

CAP

2. Pressing the MODE key until the “nF” symbol is shown at display to meaning the

capacitance measurement

3. Insert the test leads into the jacks, the red plug into V

TempHz%CAP

jack and

black plug into COM jack (see Fig. 7)

4. Press the REL key before start the measurement
5. Connect the red and black test clamps to the capacitor terminals respecting if

necessary the proper polarities. The capacitance value is shown on display

6. If the message "

O.L

" is displayed the higher range is reached

7. For HOLD function and Relative measurement please refer to paragraph 4.2