HT instruments HT322 User Manual

Page 15

Advertising
background image

HT321 - HT322

EN - 14

6.1.1. Safety
The instrument complies with:

IE/EN61010-1

Insulation:

double insulation

Pollution degree:

2

Overvoltage category:

CAT III 1000V, CAT IV 600V

Max height of use:

2000m (6561ft)

6.1.2. General data
Mechanical characteristics
Dimensions (L x W x H):

163 x 88 x 48mm (6.4 x 3.5 x 1.9in)

Weight (including battery):

280g (9.9 ounces)

Power supply
Battery type:

2 x1.5V batteries type AAA MN2400 LR03 AM4

Indication of low battery:

symbol "

" is displayed

Battery life:

Approx. 220 hours

Display
Specifications:

3½ LCD with max. reading 1999 counts +
symbol and decimal point

6.2. ENVIRONMENT
6.2.1. Environmental

conditions

Reference temperature:

23 ± 5°C; 73 ± 41°F

Working temperature:

-5 ÷ 40°C; 23 ÷ 104°F

Relative humidity:

<80% HR

Storage temperature:

-10 ÷ 60°C; 14 ÷ 140°F

Storage humidity:

<70% HR

This product conforms to the prescriptions of the European directive on low voltage

2006/95/EEC (LVD) and to EMC directive 2004/108/EEC.


6.3. ACCESSORIES
6.3.1. Standard

accessories

 Test

leads

 Batteries
 B80: carrying case
 User

manual


6.3.2. Optional

accessories

Couple of test leads

Cod. 4413-2

Adapter for connection type K probe (HT322 only)

Cod. T10

K-type probe for air and gas temperature (HT322 only)

Cod. TK107

K-type probe for semisolid substance temperature (HT322 only)

Cod. TK108

K-type probe for liquid substance temperature (HT322 only)

Cod. TK109

K-type probe for surface temperature (HT322 only)

Cod. TK110

K-type probe for surface temperature with 90° tip (HT322 only)

Cod. TK111


Advertising