7. TECHNICAL SPECIFICATIONS

7.1. TECHNICAL

CHARACTERISTICS

Voltage Test
Test Range:

60-250V AC

Frequency Range:

40-60 Hz

Test Current:

< 200mA


Lamp Test
Voltage with new battery:

approx. 3kV / 280kHz

Field strength 150-170 kHz:

approx. 100 µV/m

Display:

“Test” LED on and acoustic signal


Continuity Test
Dielectrical Strength:

250V AC/DC

Test Range:

approx. 0-5 MΩ

Test Current:

< 7 µA

Display: “Continuity/Voltage”

LED on and acoustic signal


7.2. GENERAL

CHARACTERISTICS

Power supply
Internal power supply:

1x9V battery NEDA1604, JIS006P, IEC6F22


Mechanical characteristics
Dimensions (LxWxH):

255 x 60 x 40mm; 10 x 2 x 1in

Weight (battery included):

approx 170g; 5 ounces


Safety standards
Compliance with standard: IEC/EN61010-1
Insulation: double

insulation

Overvoltage category:

CAT II 300V

Max altitude:

2000m (6562ft)


7.3. ENVIRONMENT
7.3.1. Environmental conditions of use
Reference calibration temperature: 23 ± 5°C; (73 ± 41°F)
Operating temperature:

0 ÷ 40°C; (32 ÷ 104°F)

Allowable relative humidity:

<70%HR

Storage temperature:

-10 ÷ 50°C; (14÷ 122°F)


This instrument satisfies the requirements of Low Voltage Directive 2006/95/EEC

(LVD) and of EMC Directive 2004/108/EEC


7.4. ACCESSORIES
7.4.1. Standard accessories

• Battery (not fitted)

• User

manual