6 technical specifications – HT instruments HT9012 User Manual

Page 15

Advertising
background image

HT9012

EN - 14

6 TECHNICAL

SPECIFICATIONS

6.1 CHARACTERISTICS
Accuracy is calculated as [% rdg + (n°of dgt) * resolution] referred to: 23°C ± 5°C <80%RH

DC Voltage

Range Resolution Accuracy

Input

impedance

Overload

protection

200.0mV 0.1mV

2.000V 0.001V
20.00V 0.01V
200.0V 0.1V

1000V 1V

±(1.0%rdg + 3dgt)

10M

1000VDC/ACrms

The meter emits a continuous sound with VDC >1000V


AC Voltage

Range Resolution

Accuracy

(50

÷ 60Hz)

Input

impedance

Overload

protection

200.0mV 0.1mV

±(1.5%rdg + 15dgt)

2.000V 0.001V
20.00V 0.01V
200.0V 0.1V

1000V 1V

±(1.0%rdg + 4dgt)

10M

1000VDC/ACrms

Integrated sensor for AC voltage detection: LED turn on for phase-earth voltage > 100V, 50/60Hz
The meter emits a continuous sound on 1000V range for VAC>750V

AC Current

Range Resolution Accuracy

(*)

Frequency

range

Overload

protection

2.000A 0.001A

±(2.5%rdg + 10dgt)

20.00A 0.01A
200.0A 0.1A

±(2.5%rdg + 4dgt)

600A 1A

±(3.0%rdg + 4dgt)

50

÷60Hz

600Arms

(*) Referred to cable inside to the center of clamp jaws

Position sensitivity:

±2.0%rdg

Resistance and Continuity test

Range Resolution Accuracy

Buzzer

Overload

protection

200.0

Ω 0.1Ω

2.000k

0.001k

20.00k

0.01k

200.0k

0.1k

2.000M

0.001M

±(1.0%rdg + 5dgt)

20.00M

0.01M

±(2.0%rdg + 10dgt)

≤100

600VDC/ACrms


Diode test

Features

Test current

Open voltage

0.3mA typical

1.5VDC