Electrical Connections

4.4

AC ELECTRICAL CONNECTIONS

Danger
Make sure that power to the instrument is disconnected
before making any wiring connections.

CONNEXIONS AUX COURANT SECTEUR / ALTERNATIF

Danger
Débrancher toute alimentation à l'appareil avant de
connecter les fils.

1. Use a Phillips-head screwdriver to remove the screws from the enclosure lid.
2. Remove the lid.
3. Run the AC power conduit/cord up through the bottom left opening on the

bottom of the enclosure.

4. Connect the conduit wires as described in Table 1and Figure 5.
5. Replace the cover.

6. Replace the cover screws.

FIGURE 5. AC wiring connections

Table 1. Aqua Con TROLL AC wiring connections

Pin

Description

North American Wire Color

European Wire Color

L

Line

Black

Brown

N

Neutral

White

Blue

Protective Earth

Shield

Green and yellow

Ground

Neutral

Line

Pre-wired at factory

Run conduit through enclosure to terminals