Connects a Level TROLL directly to a controller or logger for communication via:

• Analog (4-20 mA)

• RS485 Modbus

• SDI-12

• RS232 Modbus (with a customer-supplied converter)

Twist-Lock connector mates with probe body. Stripped & tinned wires on opposite end
for wiring to PLC or logger. Vented cable includes removable outboard desiccant to
protect cable vent tube from condensation in high-humidity environments.

CABLE SPECIFICATIONS
Jacket options

TPU (Thermoplastic Polyurethane)
Halogen-Free TPU (LSZH-rated, low smoke zero halide)
FEP (fluorinated ethylene propylene, generic equivalent of
DuPont Teflon

®

)

Vent options

Vented (includes outboard desiccant), non-vented

Conductors

6 conductors, 24 AWG, polypropylene insulation

Diameter

Cable, 6.7 mm (0.265 in); Connector, 18.5 mm (0.73 in)

Minimum bend radius

2X cable diameter (13.5 mm, 0.54 in)

Break strength

127 kg (280 lb)

Max. recommended

SDI-12

61 m (200 ft)

cable lengths

Modbus

1259 m (4000 ft)

4-20 mA

1259 m (4000 ft)

Desiccant pack

Clear acrylic, nylon, HDPE membrane

Desiccant

approx. 22 g silica gel, type 4

CONNECTIONS
Refer to wiring diagrams on back of sheet. Trim back and insulate unused wires. The
shield should be wired to a chassis ground or earth ground.

Power Connections. The Red wire provides power for Modbus and SDI-12 modes.
The Brown wire provides power for the 4-20 mA mode. If power is present on the Brown
wire and not on the Red wire, the device enters the 4-20 mA mode automatically and
stays in the 4-20 mode until power is removed from the Brown wire or is applied to the
Red wire. The Red wire has priority — if power is applied to both wires at the same time,
the device will operate in Modbus or SDI-12 modes but not in 4-20.

Communications. The device automatically switches between Modbus and SDI-12
modes depending on which of the two interfaces has activity. Modbus and SDI-12
cannot be used at the same time — whichever one is currently in use will block commu-
nication on the other.

To communicate with the Level TROLL using Win-Situ

®

5 software through a serial COM

port: Cable can be wired to a port-powered RS485-RS232 converter* for temporary
connection to a serial port on a PC.

Signal

Color

Gnd/Return

BLACK

Ext Power

RED

4-20 mA

BROWN

RS485(–)

GREEN

RS485(+)

BLUE

SDI-12

WHITE

RuggedCable (TPU)

Signal

Color

Gnd/Return

BLACK

Ext Power

RED

4-20 mA

BROWN

RS485(–)

GREEN

RS485(+)

ORANGE

SDI-12

YELLOW

FEP Cable

and
secured to
cable with
strap

Outboard
desiccant
attached to
cable vent
tube

Dust cap
Remove
before use

TIP: The desiccant may be removed
from the vent tube, if needed, for
better access to the conductor wires.

Pull the vent tube extender off the cable vent
tube to remove. After connecting and trimming
wires, attach desiccant vent tube to cable vent
tube and secure desiccant to cable with hook-
and-loop strap, as shown in the photo above.