BOP 20-20MC/031512
In Current Mode the dynamic specifications are almost identical for all BOP MC and DC
models: 3-dB bandwidth of 4.9kHz and rise/ fall time of 72
µs (lower bandwidth and higher rise/
fall time than standard BOP M and D models).
FIGURE 1. ASSEMBLY A1, EXTERNAL BANDWIDTH CORRECTION CAPACITOR LOCATIONS