BOP 1000W QUICK REFERENCE GUIDE

Once the power supply is installed (see full Technical Manual), this guide is an aid that briefly outlines a simple approach to accomplishing
common tasks, with the appropriate Technical Manual paragraph references for more details. All instructions start from the power-up
screen (press

%

from most submenus to return to power-up screen). Many setup functions can be password protected - see UTILITY

below for instructions.

UTILITY

How do I access a password-protected menu?

Enter first character of password using ADJUST control or keypad (use multiple

presses of the keys for letters or symbols:

0

(space),

1

(+, –, /),

2

(ABC),

3

(DEF),

4

(GHI),

5

(JKL),

6

(MNO).

7

(PQRS),

8

(TUV),

9

(WXYZ).

T

to enter next character,

!

to verify. If incorrect, press CLEAR and repeat (see PAR. 3.2.4.4).

How do I use the keypad?

STANDBY sets output on/off (STANDBY indicator lit when output off), MODE selects voltage mode or cur-

rent mode, arrow keys highlight selections, numbers enter values and multiple presses can enter alphanumeric characters, +/– sets sign,
CLEAR sets numeric values to zero, clears alphanumerics, RESET is equivalent to power-up cycle, ENTER applies settings to output and
saves changes, HELP is context sensitive, keep pressing for more,

!

through

%

functions are defined by graphic box to the left (see

PAR. 3.2.1).

How do I use the ADJUST control?

Adjusts value of highlighted digit, fine adjustment (least significant digit) if held in while adjusting.

If output is on, directly controls output (pressing ENTER not required). Scrolls through all alphanumeric characters for password.

How do I turn the beep on or off?

#

, highlight Key Press Beep,

!

, highlight On, Error only or Off, then

$

.

%

to exit or

$

to

save for power-up (see PAR. 3.2.5.2).

How do I set the display background to black or white?

#

, higlight Background,

!

, highlight Black or White, then

$

.

%

to

exit or

$

to save for power-up (see PAR. 3.2.5.1). If

$

not available, see NOTE to PAR. 3.2.5).

How do I adjust the Display contrast?

#

,

#

, then

#

when contrast is OK.

R

or

T

for fine adjustment.

%

to exit or

$

to

save for power-up (see PAR. 3.2.5.1). If

$

not available, see NOTE to PAR. 3.2.5).

How do I choose between graphical meters or time line graphs?

:

#

, Higlight Graphic Display,

!

, highlight Meters or the

appropriate Graph time, then

$

.

%

to exit or

$

to save for power-up (see PAR. 3.2.5.3).

CONTROLLING THE OUTPUT USING THE FRONT PANEL (LOCAL)

How do I apply a voltage or current to the load?

If output is on (STANDBY indicator not lit) press STANDBY to turn output off

(STANDBY indicator lit). Use MODE to select Voltage or Current mode, use

Y

or

U

to highlight main channel, use keypad to set value,

then press ENTER. Highlight protect channel(s) and use keypad to set value. then press ENTER. Press STANDBY to turn output on and
apply programmed settings to load (see PAR. 3.3.3).

How do I change between a single value or two different values for positive and negative protection limit?

%

, high-

light Max/Min Settings,

!

, Higlight Protect Entry,

!

, highlight Bipolar or Independent, then

$

.

%

to exit or

$

to save for power-up

(see PAR. 3.3.3.1).

How can I prevent voltage (in voltage mode) or current (in current mode) from being set beyond a predetermined

level?

%

, highlight Max/Min Settings,

!

. Higlight +Voltage Max, -Voltage Min, +Current Max or -Current Min as desired,

!

, use key-

pad to change value, then

$

.

%

to exit or

$

to save for power-up (see PAR. 3.3.4).

How do I prevent protection limit from being set beyond a predetermined level?

%

, highlight Max/Min Settings,

!

,

Higlight +C Protect Max, -C Protect Min, +V Protect Max or -V Protect Min as desired,

!

, use keypad to change value, then

$

.

%

to

exit or

$

to save for power-up (see PAR. 3.3.4.2).

What happens when the protect setting is reached?

Limit channel controls power supply, display shows the message CPRO-

TECT (current protection in voltage mode) VPROTECT (voltage protection in current mode) or PROTECT (external analog protection).

POWER SUPPLY SETUP

How do I configure for resistive, active or battery type load?

%

, highlight Load Type,

!

, highlight Active, Resistive, or Bat-

tery then

$

. Press

%

to exit or

$

to save for power-up (see PAR. 3.3.6).

How do I control whether the output is on or off upon *RST?

%

,

!

, highlight *RST sets Output,

!

, highlight On or Off, then

$

. Press

%

to exit or

$

to save for power-up (see PAR. 3.5.3.1.3).

How do I control what condition the unit is in upon power up.

%

, highlight Power Up Settings,

!

, highlight parameter,

!

,

highlight desired power-up state, then

$

. Repeat for all parameters, then

%

to exit or

$

to save for power-up (see PAR. 3.3.7).