KEPCO CA 41-R User Manual

Ca 41-r, Kepco, Enclosures and hardware systems

Advertising
background image

©200

8, KEPCO, INC

Data subject to change without notice

228-1639

I N S T R U C T I O N S H E E T

KEPCO

KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102

http://www.kepcopower.com " email: [email protected]

An ISO 9001 Company.

CA 41-R

COVER

ENCLOSURES AND

HARDWARE SYSTEMS

DESCRIPTION.

The Kepco Model CA 41-R RoHS Compliant Cover (see Figure 1 below) is supplied for use with

Kepco MTW 60W Series Power Supplies. The easily installed, two-part steel cover is an option designed for shield-

ing and protection. Required installation hardware is provided. Refer to Figure 2 for outline dimensions.
1 Remove top cover from bottom cover by removing tape (not shown), disengaging tabs marked (A), and sliding

cover forward. Remove and retain hardware from poly bag (not shown) taped to bottom cover.

2 Position MTW 60W Power Supply over the four threaded spacers on the bottom cover marked (B), as indicated,

with input connector positioned towards cutout marked (E).

3 Fasten MTW 60W Power Supply to bottom cover with four 6-32 x 3/8 in. Phillips screws (PN 101-0156) marked

(C), and four #6 lockwashers (PN 103-0015).

4 Drop cover in place by engaging tabs marked (A) and sliding cover backward. Secure bottom cover to top cover

with two M3 x 5 screws (PN 101-0435) marked (D).

Connections to input and output connectors are via cutouts on top cover.

FIGURE 1. COVER INSTALLATION

Advertising