B.54 [source:]voltage:protection:over command, B.55 [source:]voltage:protection:over? query, B.58 [source:]voltage:protection:under command – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 3.87 to 3.xx User Manual

Page 73: B.59 [source:]voltage:protection:under? query, B.53, Source, B.54, B.55, B.56, B.57

Advertising
background image

SERIES EL 022013

B-11

B.53 [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? QUERY

VOLT?

Syntax:

Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]?
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]?
Returns: <NR2> = voltage setpoint

Description: Indicates voltage setpoint.

B.54 [SOURce:]VOLTage:PROTection:OVER COMMAND

VOLT:PROT:OVER

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVER <NR2>
Long Form: [SOURce:]VOLTage:PROTection:OVER <NR2>
where <NR2> = overvoltage protection limit

Description: Sets overvoltage protection limit. Overvoltage protection setpoint is stored in non-volatile memory;

value is restored upon power-up.

B.55 [SOURce:]VOLTage:PROTection:OVER? QUERY

VOLT:PROT:OVER?

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVER?
Long Form: [SOURce:]VOLTage:PROTection:OVER?
Returns <NR2> = overvoltage protection limit

Description: Indicates overvoltage protection limit.

B.56 [SOURce:]VOLTage:PROTection:OVER:STATe[:LEVel] COMMAND

VOLT:PROT:OVER:STAT 0

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVER:STAT[:LEV] 0
Long Form: [SOURce:]VOLTage:PROTection:OVER:STATe[:LEVel] 0

Description: Clears overvoltage protection error.

B.57 [SOURce:]VOLTage:PROTection:OVER:STATe[:LEVel]? COMMAND

VOLT:PROT:OVER:STAT?

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVER:STAT[:LEV]
Long Form: [SOURce:]VOLTage:PROTection:OVER:STATe[:LEVel]
where <bool> = 1 (overvoltage protection error occurred)

0 (overvoltage protection error has not occurred)

Description: Indicates whether an overvoltage protection has occurred (1) or not (0).

B.58 [SOURce:]VOLTage:PROTection:UNDer COMMAND

VOLT:PROT:UND

Syntax:

Short Form: [SOUR:]VOLT:PROT:UND <NR2>
Long Form: [SOURce:]VOLTage:PROTection:UNDer <NR2>
where <NR2> = undervoltage protection limit

Description: Sets undervoltage protection limit. Undervoltage protection setpoint is stored in non-volatile mem-

ory; value is restored upon power-up.

B.59 [SOURce:]VOLTage:PROTection:UNDer? QUERY

VOLT:PROT:UND?

Syntax:

Short Form: [SOUR:]VOLT:PROT:UND?

Long Form: [SOURce:]VOLTage:PROTection:UNDer?

Returns: <NR2> = undervoltage protection limit

Description: Indicates undervoltage protection limit.

Advertising