KEPCO HSF 600W Series (no suffix, suffix M and MZ) Quick Start Guides User Manual

600w, Kepco, Single output 3u hot swap plug-in power supplies

Advertising
background image

©2013, KEPCO, INC

1

Data subject to change without notice

228-1705 REV 1

KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102

http://www.kepcopower.com " email: [email protected]

Q U I C K S T A R T G U I D E

KEPCO

An ISO 9001 Company.

HSF

600W

SINGLE OUTPUT 3U

HOT SWAP PLUG-IN POWER SUPPLIES

I — INTRODUCTION

SCOPE OF MANUAL. This Quick Start Guide covers

the installation and operation of the Kepco HSF 600W
Series of Hot Swap Plug-in Power Supplies. Full specifica-
tions are listed in the applicable 600W standard (non-
metered), and metered (M, MZ) HSF Operator Manual that
can be downloaded from the Kepco web site at:
www.kepcopower.com/support/opmanls.htm#hsf

These power supplies are designed to be installed in
Kepco’s RA 19-4C Rack Adapter. The RA 19-4C Operator
Manual can be downloaded from the Kepco web site at:
www.kepcopower.com/support/opmanls.htm#ra19-4c

FACTORY DEFAULTS. This guide covers only units as

shipped from the factory with the two internal DIP switches
set to default configuration (see Figure 1). For other config-
urations, refer to applicable Operator Manual.
DESCRIPTION. The Kepco HSF 600 Watt Series are hot

swappable, high frequency switching, plug-in power sup-
plies. Models may be selected for outputs of 12V, 15V, 24V,
28V or 48V. They employ power factor correction and are
designed to operate in a fault tolerant power system with a
nominal a-c input of 100V a-c to 240V a-c (input voltage
range 85 to 265 Va-c), 50-60 Hz (input frequency range 47-
440Hz). A built-in current balancing circuit and OR-ing
diodes allow configuration for hot-swap and parallel-redun-
dant N+1 operation.

OPTIONS. M and MZ models include a digital meter

which displays either voltage or current as determined by a
front panel switch. M Models require a minimum output
voltage to power the meter, alarm relay and VDC ON indi-
cator and for proper load sharing in parallel configura-
tions.

FIGURE 1. DIP SWITCH FACTORY DEFAULTS

MZ models can be adjusted down to 0V output without
affecting operation of meter, alarm relay, VDC ON indica-
tor, or parallel load sharing. C models allow independent
current monitoring of non-metered models. RoHS-compli-
ant models indicated by HSF* (e.g., HSF 28*23M).

II — INSTALLATION

PRIOR TO MOUNTING. Two internal DIP switches are

preconfigured for the factory defaults listed above. To
change the factory defaults, refer to the applicable operator
manual and configure the DIP switches prior to installation.

KEYING. The units are keyed by voltage at the factory.

Refer to the RA 19-4C Operator Manual to make the rack
adapter slot match the HSF.

MOUNTING THE POWER SUPPLY. Release the two

cap head screw retaining latches (see Figure 2) by loosen-
ing the cap-head screw approximately 1/2 turn CCW (use
5/32" hex key) and slide to open (up) position. Insert power
supply in the slot, then retighten the cap-head screws CW
until snug. DO NOT OVERTIGHTEN! To release, follow the
same procedure, except lift the latch to the top of the slot.
Be sure to move the latch completely up or down to ensure
full engagement/disengagement of the latching mecha-
nism. When HSF is not installed in rack adapter, secure
latch in open (up) position to prevent damage.

3043514

- FRONT PANEL VADJ CONTROL
- RELAY ALARM SELECTED
- VISUAL ALARM DISABLED
- REMOTE ON-OFF DISABLED
- DC ON PWR BY REF V ENABLED

8

8

8

- FRONT PANEL VADJ CONTROL
- RELAY ALARM SELECTED
- VISUAL ALARM DISABLED
- REMOTE ON-OFF DISABLED
- DC ON PWR BY REF V ENABLED

4

SW2

8

8

SW1

7

5
6

6
7

5

SW2

OFF

4

3

2

1

2
3

1

SW1

OFF

ON

ON

8

7

6

5

4

3

2

1

4

4

6
7 7

5 5

6

6
7

5

3

4

3

2

1

2

1

3

2

1

OFF

ON

OFF

ON

Factory default

settings for

standard,

M and C

options

Factory default

settings for

MZ option

2

2

6

8

7

4

5

3

6

8

7

4

5

3

1

1

TAB

TABLE 1. HSF 600W HOT SWAP MODELS

MODELS

12V

15V

24V

28V

48V

600W

HSF 12-53

HSF 15-43

HSF 24-27

HSF 28-23

HSF 48-13

NOTE: Options include suffix M, MZ, or C: M or MZ for meter; C for current monitor, HSF* indicates RoHS compliance.

Advertising