KEPCO HSF 300W Series (no suffix) Operator Manuals User Manual

Page 6

Advertising
background image

4

HSF 300W 050113

Overvoltage Protection

When the Power Supply goes into an overvoltage condition, the output is cut OFF. See PAR.
3.6.1.

Remote Control ON/OFF:

±RC pins control on/off as follows:
“High”, 2.4V to 24V (or open), unit OFF- Fan Off;
“Low”, 0.0V to 0.4V (or closed), unit ON.
Source current: 1.6mA maximum at low level
Sink current: 1.0 mA maximum at high level.

Must be enabled by DIP switch positions 3
and 4 (see PAR. 3.5).

Operating Temperature:

-10 to 40°C

(see Figure 2.)

Startup Temperature

-10 to -20°C

(see Figure 2.)

Storage Temperature:

-30°C to +75°C

Withstanding voltage : (at 15-35°C
ambient, 10-85% relative humidity)

2000Va-c for 1 minute. Cutout current is 20mA

Between input and ground

500Va-c for 1 minute. Cutout current is 100mA

Between output and ground

3000Va-c for 1 minute. Cutout current is 20mA

Between input and output terminal

Insulation Resistance: (at 25°C,
65% relative humidity)

100 Megohms minimum (500Vdc)

Between output and ground, input and

ground, and input and output,

Humidity:

10% to 95% relative humidity, noncondensing,
Wet Bulb temperature <35°C

operating and non-operating

Vibration:

5-10 Hz., 10mm amplitude, 10-55 Hz., accelera-
tion 64.3ft./s

2

(19.6M/s

2

) (2g)

non-operating 1 hr. on each of 3 axes,

sweep time 10 minutes

Shock: Acceleration:

643.5ft./s

2

(196.1M/s

2

) (20g),

Pulse Duration: 11ms ± 5 msec

(non-operating, 1/2 sine pulse, three

shocks on each axis, Power Supply is

fixed on its bottom side)

Safety:

Designed to meet UL: 60950; CSA:C22.2 60950; TUV: EN60950.

EMC Emission - Conducted:

Designed to meet FCC Class B, VCCI-Class B, EN55011-B, EN55022-B

EMC Emission - Radiated:

Designed to meet FCC Class B, VCCI-Class B, EN55011-B, EN55022-B

EMC Emission - Input harmonics
current:

Designed to meet EN61000-3-2

EMC Immunity

Designed to meet EN61000-6-2

EMC Radiated susceptibility:

EN61000-4-3 level 3

normal operation

EMC Conducted susceptibility:

EN61000-4-6 level 3

normal operation

ESD:

EN61000-4-2, level 4 (HSF 5-60M: level 3)

normal operation

Electrical fast transient burst:

EN61000-4-4 level 3

normal operation

Surge withstand:

EN61000-4-5, level 4 (HSF 5-60M: level 3)

No damage

Power Frequency Magnetic Field:

EN61000-4-8, level 4 (HSF 5-60M: level 3)

normal operation

Voltage dips interruptions and
variations

EN61000-4-11

normal operation

Dimensions:

5.22 in. (132.5 mm) x 4.288 in. (108.9 mm) x 16.86 in. (428.2 mm) (See Figure 3)

Mounting: Plug-in

Cooling:

Forced air flow - fan

Frame Material/Cover Material:

Steel

Weight

8 lbs, 3.7Kgs. maximum

TABLE 3. POWER SUPPLY RATINGS AND SPECIFICATIONS (CONTINUED)

CHARACTERISTIC

SPECIFICATION

CONDITION/NOTES

Advertising