Table 2. output ratings and specifications, Output ratings and specifications, 2 co – KEPCO HSF 600W Series (no suffix, suffix C) Operator Manuals User Manual

Page 5

Advertising
background image

HSF 600W 022713

3

FIGURE 2. POWER RATING VS. TEMPERATURE (INPUT: 95 TO 264V A-C)

TABLE 2. OUTPUT RATINGS AND SPECIFICATIONS

MODEL

HSF 12-53

HSF 15-43

HSF 24-27

HSF 28-23

HSF 48-13

Output Volts d-c (nominal)

12

15

24

28

48

Output

Adjustment

Range

(1)

Using front panel trim pot or

external 5K ohm Trimpot

(Volts d-c)

(2)

0 - 13.8

0 - 17.4

0 - 28.2

0 - 33

0 - 52.2

Using Voltage source

(Volts d-c)

0 - 13.8

0 - 17.4

0 - 28.2

0 - 33

0 - 52.2

Output Current (nominal) (Amps d-c)

53

43

27

23

13

Maximum Output Ratings

(3)

(Watts)

636

645

648

644

624

Overcurrent Setting (Amps d-c)

(4)

55.6-68.9

45.1-55.9

28.3-35.1

24.1-29.8

13.7-16.9

Short Circuit Current (Amps d-c)

65

55

35

29

19

Overvoltage Protection (OVP) (Volts d-c)

(5)

14.3 - 16.8

18.0 - 21.0

29.3 - 33.6

34.2 - 39.2

54.5 - 59.8

Efficiency

% typical

AC Input 100V

80

81

82

82

84

AC Input 200V

84

85

86

86

87

Power Factor

(typ.)

AC Input 100V

0.99

0.99

0.99

0.99

0.99

AC Input 200V

0.95

0.95

0.95

0.95

0.95

Ripple &

Noise

(6)

(mV, p-p)

ripple 180

180

220

220

220

ripple noise

220

220

320

320

320

Sense Resistor (IMON) values (Ohms)

(7)

0.002

0.005

0.01

0.01

0.02

(1)

Refer to Table 4 for minimum conditions required to maintain proper operation of alarm relay and visual LED indicator.

(2)

Output voltage may not adjust to 0V due to residual trimmer resistance.

(3)

See Figure 2 for power derating.

(4)

Square type. Output voltage returns automatically only if cause is removed within 30 seconds (see PAR. 3.6.2).

(5)

When overvoltage is detected, output is shut OFF. Recovery is by removing, and after approximately 40 seconds, reapplying
AC input power or by reset (open and close) at ±RC terminals (no delay).

(6)

Ripple and noise levels above are satisfied when conditions are 0 to 100% load, 0 to 40°C (load is derated from 40 to 55°C,
see Figure 2), and bandwidth </= 100MHz.

(7)

Option C only.

NOTE:
Safety agency approvals
apply only to operation
between -10°C and 40°C.