Recovery characteristics, Start-up time, Holdup time – KEPCO HSF-PFC 100W Series Operator Manual User Manual

Page 7: Dielectric strength, Insulation resistance, Leakage current, Safety, Vibration, Shock, Operating temperature

Advertising
background image

KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102

http://www.kepcopower.com email: [email protected]

083013

228-1533 REV 15

7

IV — SPECIFICATIONS (C, T, X, Y) - CONTINUED

RECOVERY CHARACTERISTICS: A step load

change from 50% to 100% produces less than +4% output
excursion. Recovery occurs to within +1% of the original
setting in <1 ms (load change t

r

or t

f

equal to or greater

than 50

µsec). (3.3V: 200mV max.)

START-UP TIME: 500 ms. maximum @100V a-c

400 ms. typical @100V a-c
300 ms. maximum @240V a-c
200 ms. typical @240V a-c

HOLDUP TIME:

37 ms. typ., 20 ms. min. (100V a-c)
30 ms. typ., 20 ms. min. (240V a-c)

DIELECTRIC STRENGTH:

Between input and output:

2KV a-c for one minute.

Between input and case (ground):

2KV a-c for one minute.

Between output and case (ground):

500V a-c for one minute.

INSULATION RESISTANCE: Between input and

ground, output and ground, input and output:

100 Megohms min. (500V d-c).

LEAKAGE CURRENT (per IEC 950 and UL 1950)

0.13mA typ. 0.19 mA maximum, (120V a-c)

0.45 mA maximum (240V a-c)

SAFETY: Units are designed to meet UL60950 3rd Edi-

tion, CSA 22.2 No. 60950-1, and EN60950:2001 and are
CE marked per the Low Voltage Directive (LVD), 73/23/

EEC and 93/68/EEC. The standards do not apply with DC
input operation.

EMI: Designed to meet FCC Class B (100-120V a-c) and

VCCI, EN55011-B, EN55022-B.

VIBRATION: (non-operating, one hour on each one of

the three axes):

5-10 Hz, 10 mm amplitude.
10-55 Hz, 2g acceleration.

SHOCK: (non-operating, one-half sinusoidal pulse, three

shocks to each axis):

Acceleration: 60g
Duration: 11ms +5ms

OPERATING TEMPERATURE: See Figure 4.

STORAGE TEMPERATURE: -30

o

C to +75

o

C.

RELATIVE HUMIDITY: Operating and storage: up to
95% (wet bulb temp. <35

o

C non-condensing).

FUSE: Slow Blow, 3.15A, 250V; (5 x 20 mm),

Littelfuse, P/N 2153.15PF;
Kepco P/N 541-0135.

DIMENSIONS: See Figure 6.

WARRANTY: 5 years.