KEPCO JBW 50W Series User Manual

50w series, Kepco, 50 watt single output switching power supplies

Advertising
background image

©2010, KEPCO, INC

1

Data subject to change without notice

228-1511 REV 1

KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102

http://www.kepcopower.com email: [email protected]

O P E R A T O R M A N U A L

KEPCO

An ISO 9001 Company.

JBW

50W SERIES

50 WATT SINGLE OUTPUT

SWITCHING POWER SUPPLIES

I — INTRODUCTION

SCOPE OF MANUAL. This instruction manual covers

the installation and operation of the Kepco JBW 50W

Series of RoHS (Reduction of Hazardous Substances)

compliant Switching Power Supplies.

DESCRIPTION. The Kepco JBW 50W Series consists of

four models of switching power supplies, each with a single

output as shown in Table 1. Units may be operated with a

nominal 100 to 120V a-c and 220 to 240V a-c (input voltage

range 85 to 265 Va-c), 50-60 Hz (input frequency range 47-

440Hz.) They will also operate on 110V to 370V d-c input.

The JBW 50W Series employs a light weight ferrite core.

Regulation is provided by pulse width modulation. A FET

power stage, operating as a forward converter with a fixed

switching frequency of 140KHz provides a smooth isolated

d-c output. A thermistor circuit prevents excessive turn-on

current surge. Overvoltage protection is provided. Current

limiting with automatic recovery from short circuit is fea-

tured. Units are manufactured on an open frame PC board.

Table 1 contains specifications and operating limits of indi-

vidual JBW 50W Series models. Section II (following) con-

tains specifications and operating limits common to all JBW

50W Series Models

II — SPECIFICATIONS

The following specifications are at nominal input voltages

and 25°C and apply to all models unless otherwise speci-

fied.

INPUT CHARACTERISTICS:

INPUT VOLTAGE: (0 to 100% load, -10 to 60°C)

Nominal 100-120V a-c, 220-240V a-c

Range: 85-265V a-c, 110 -370V d-c

NOTE: The power supply may shut down if operated at

below the input voltage range or if the input voltage

increases slowly at start up (> 1 second). To reset the

power supply, unplug the unit, wait one minute and

reapply input power.

INPUT SOURCE FREQUENCY:

Nominal 50/60 Hz;

Range 47-440 Hz (Above 66Hz to 440 Hz the leakage

current may exceed the VDE safety specification limit,)

INPUT CURRENT: (100% load at 25°C with nominal out-

put voltage):

100V a-c input:

All except 24V Model:

0.7A typ., 0.88A max.

24V Model:

0.8A typ., 0.88A max.

240V a-c input:

0.35A typ., 0.5A max.

INPUT PROTECTION AND SOFT START: A thermis-

tor circuit reduces start-up surge. Units are protected

against shorts by an input fuse. Fuse value 3.15A,

250V.

INPUT SURGE: Cold start:

100V a-c input, 100% load: 15A typ., 30.0A max.

240V a-c input, 100% load: 40A typ., 60.0A max.

TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, JBW 50W SERIES

MODEL

JBW 05-10R

JBW 12-4R3

JBW 15-3R5

JBW 24-2R1

OUTPUT VOLTS, d-c

5V

12V

15V

24V

ADJUSTMENT RANGE

4.5-5.5V

10.8-13.2V

13.5-16.5V

21.6-26.4V

CURRENT/POWER

RATINGS

10.0A/50W

4.3A/51.6W

3.5A/52.5W

2.1A(1)/50.4W

CURRENT LIMIT (AMPS)

10.5 min

5.4 min

4.4 min

3.0 min

OVP RANGE (VOLTS)

5.75-6.9

13.8-16.8

17.2-21.0

27.6-33.6

EFFICIENCY

100 Va-c

77%

80%

80%

81

240 Va-c

79%

81%

81%

83%

ACCEPTABLE EXTERNAL OUTPUT CAPACITOR

µFmax., (fixed load resistance)

10,000

10,000

10,000

10,000

RIPPLE AND

NOISE

(2)

(mV p-p)

ripple (typ)

80

120

120

120

ripple (typ) (-10 to 0

°C)

140

160

160

160

spike noise (typ)

120

150

150

150

spike noise (typ)

(-10 to 0

°C)

160

180

180

180

(1)

2.6A peak, t

10 seconds, not to exceed 2.1A rms, output power

50.4W.

(2)

0 to 100% load, 0 to 60 °C, tested with 100µF electrolytic and 0.1µF film capacitors across the measuring points, connected to the power supply
via 5.9 in (150mm) wires; oscilloscope bandwidth

20MHz.

Advertising