BUS BAR

219-0429

KIT

BUS BAR LINKS KIT NO. 219-0429

DESCRIPTION.

Adjacent positions of the RA 59 rack adapter can be reconfigured for parallel/redun-

dant operation by installing optional bus bar links as shown in Figure 1. The kit consists of two bus bar

links and the associated attaching hardware (see Figure 1) used to connect the (+) and (–) terminals of

an adjacent pair of power supplies.

NOTE: To connect all four power supplies of the RA 59 rack adapter for parallel/redundant operation,

three bus bar link kits, P/N 219-0429, are required.

PROCEDURE.

BE SURE ALL POWER IS DISCONNECTED FROM

RACK ADAPTER BEFORE DISASSEMBLY.

1.

Remove eight screws (2, Figure 1) and eight lockwashers (1) securing the four l/O connector

assemblies (10) to the chassis (9).

2.

Remove 12 screws (8) from the top, bottom, and sides of chassis (9). Carefully separate back-

plate assembly (3) from chassis (9) and swing down (with wires attached) to expose bus bar

links (4).

3.

To install a bus bar link (4), use four screws (7), lockwashers (6), and flat washers (5) to attach

bus bar link (4) to backplate assembly (3).

4.

To remove a bus bar link (4), remove four screws (7), lockwashers (6), and flat washers (5)

securing bus bar link (4) to backplate assembly (3).

5.

Assemble backplate assembly (3) to chassis (9) (taking care that wires are not crimped) using

eight screws (2) and lockwashers (1).

6.

Secure backplate assembly (3) to chassis (9) using 12 screws (8)

WARNING