KEPCO KIT 219-0481, Kit for connecting three series-connected 1000W BOPs in two parallel branches (3X2) User Manual

Cable, Kepco

Advertising
background image

©2012, KEPCO, INC
Data subject to change without notice

228-1523 REV 3

033012

I N S T R U C T I O N S H E E T

KEPCO

KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102

http://www.kepcopower.com email: [email protected]

An ISO 9001 Company.

CABLE

219-0481

KIT

CABLE KIT NO. 219-0481

BOP 1000W MODELS 3 X 2 COMBINATION

I.

DESCRIPTION.

This kit contains the cables and terminations required to operate a multiple unit combination consisting of two

parallel branches each comprised of three identical 1000 Watt BOP High Power models in series, effectively tri-

pling the output voltage and doubling the output current capacity. Only identical models may be configured to

operate in parallel and series.
This kit can be used with all 1000W BOP models that have revision levels as shown in Table 1. Earlier models

that have been upgraded to permit multiple unit configurations must include the letter “A” following the revision

number. CAUTION: Failure to install the ground cables supplied can result in damage to the power supply.

Refer to the associated technical manual supplied with the 1000W BOP power supply for all instructions regard-

ing installation and operation of multiple units in parallel.

II.

SPECIFICATIONS

Table 3 lists the model parameters unique to a 3 X 2 multiple unit combination of identical 1000W BOP Power

Supplies (three series-connected units X two parallel branches). Table 4 lists the general specifications applicable

to all 3 X 2 multiple unit combinations listed in Table 3. For specifications not listed in Table 3, refer to the General

Specifications provided in the associated technical manual supplied with each 1000W BOP power supply.

TABLE 1. REVISION LEVELS APPLICABLE TO THIS KIT

MG Model

Revision

Revisions for previously Upgraded

Units (Must include “A”)

GL Model

Revision

BOP 6-125MG

All

All

BOP 10-75MG

5 or higher

3A or 4A

BOP 20-50MG

8 or higher

5A, 6A or 7A

BOP 20-50GL

All

BOP 25-40MG

All

All

BOP 36-28MG

11 or higher

8A, 9A or 10A

BOP 50-20MG

7 or higher

5A or 6A

BOP 50-20GL

All

BOP 72-14MG

7 or higher

6A

BOP 100-10MG

6 or higher

2A or 4A

TABLE 2. EQUIPMENT SUPPLIED

Item

Quantity

Purpose

Kepco Part

Number

Parallel power cable, **

(4.5 ft.)

2

Connects the OUTPUT terminal of Slave #2 to the OUTPUT terminal of Slave
#5 and the COMMON terminal of Master to the COMMON terminal of Slave #3.

118-1155

Series Power cable,

(1.5 ft.)

4

Connects the OUTPUT terminal of Master to the COMMON terminal of Slave
#1, OUTPUT terminal of Slave #1 to the COMMON terminal of Slave #2, OUT-
PUT terminal of Slave #3 to the COMMON terminal of Slave #4, and OUTPUT
terminal of Slave #4 to the COMMON terminal of Slave #5.

118-1112

Configuration Control cable,

(2.5 ft.)

1

Connects the PAR/SER CONTROL - IN ports of the Master and Slave #3
together to provide control signals needed to establish a series-parallel configu-
ration

118-1158

Series Control cable, (1.5 ft.)

4

Provides control signals required for series operation.

118-1120

** For GL units: Unclamp and remove ferrite from cable before installation.

!

Advertising