1. DESCRIPTION

Kepco KIT 219-0533 contains the PROMs used to upgrade the firmware for BOP 1000W power supplies. The

upgraded firmware supports faster serial communication, faster measurement rate, and improves LIST command

functionality:

• Provides ability to trigger external devices during execution of a lists generated either remotely via SCPI

commands or from the front panel.

• Provides ability to use trigger input of BOP to step through a list.

• Provides repeat functionality to speed up list creation.

• Provides ability to control what appears at the output when stopping a list executed from the front panel.

• Provides ability to assign different values for positive and negative limits upon startup.

• Supports 0.001 Hz sine and triangle waveform operation.

2. APPLICABILITY

This KIT applies only to

• Models BOP 72-14MG and BOP 100-10MG, all revisions

• Models BOP 10-75-MG, revision 3 and higher

• Model BOP 36-28MG, revision 7 and higher

• Models BOP 50-20MG and BOP 20-50MG, revision 1 and higher

NOTE: For revisions not listed above, please consult factory.

Kepco can provide firmware that has been pre-configured for a particular unit. The serial number of the unit is

added to part number of the kit to indicate the unit to which the kit applies.

When the upgrade is complete, a five digit number is added to the Model number of the modified unit to identify the

upgrade(s) installed.

3. INSTALLATION INSTRUCTIONS

3.1 MATERIAL REQUIRED (See Table 1.)

3.2 PRELIMINARY PROCEDURE

1. Prior to upgrade, turn on unit and note the serial number when it is displayed during power-up. Record Serial

number for configuration after upgrade is complete.

2. If pre-configured chip is provided, verify the serial number of the unit matches the serial number of the kit (KIT

2190533-[serial number]

3.3 DISASSEMBLY PROCEDURE

1. Turn power off, disconnect the unit from source power and remove line cord.

2. Remove the two mounting ears from the chassis by removing three screws from each.