1. DESCRIPTION

Kepco KIT 219-0538 contains the PROM used to upgrade the firmware for KLP 1200W power supplies from Ver-

sion 7.xx to Version 8.xx which offers the following improvements: a) baudrate is extended to 38500 (default), b)

simplified local configuration menu with added options, c) new fault recovery options, d) user-selectable remote

inhibit polarity, e) both standard (-1200) and LAN (-1.2K) models supported, f) original Operator Manual is replaced

by a CD that contains expanded KLP documentation, including a KLP Quick Start Manual, User Manual, Devel-

oper’s Guide and Labview and IVI drivers.

2. INSTALLATION INSTRUCTIONS

2.1 MATERIAL REQUIRED (SEE TABLE 1.)

2.2 DISASSEMBLY PROCEDURE

1. Disconnect all source power, load and programming cables from the power supply. If recently powered, allow

at least two minutes for the internal circuitry to discharge fully before removing the cover.

2. Note the serial number of the power supply on the nameplate located on bottom surface of the power supply

chassis.

3. Find a clean work surface with sufficient area to work on the power supply (an ESD-protected work surface is

ideal).

4. Place the wrist strap on your arm as indicated by the instructions for the wrist strap. Attach the clip to the power

supply's chassis. If the work surface is not ESD-protected, it is recommended that the chassis also be con-

nected to a known good ground potential. Do not use source power protective earthing connections

unless known to be zero potential.

5. Remove fourteen (14) flathead screws from the power supply cover: five (5) on each side surface and four (4)

on the top surface. Remove the cover by lifting it straight up. It may be necessary to apply a slight outward

force at the lower edge toward the rear of the power supply to release the cover. Set the cover and screws to

the side.

TABLE 1. MATERIAL REQUIRED

MATERIAL

LOCATION

QUANTITY

• PROM Replaces U7 on Circuit Card Assembly (CCA) A4

NOTE: PROMs are supplied preprogrammed with factory calibration

files and are identified by unit serial number on the device.

Provided in this Kit

1

• ESD (Electrostatic Discharge) wrist strap (Kepco P/N 114-0080)

Provided in this Kit

1

• PLCC PROM Extractor (Kepco P/N 114-0079)

Provided in this Kit

1

• Instruction Manual 228-1653

Provided in this Kit

1

• Documentation CD 254-0033

Provided in this Kit

1