FIGURE 2. BOP 1KW COMPONENT LOCATIONS

3. Install the 4-pin cable assembly (P/N 118-1266) on Transition Circuit A7A3J3 of the PCB (see Figure 1). Route

the cables as shown by Figure 6. This cable has three (3) unterminated wires. Determine the needed length,

cut the wire and remove the insulated sleeving (approximately 0.15"), then solder each wire to the indicated

point (see Figure 3 for A4A8 component locations and Figure 6 for cable routing):

• red wire to A4A8D1 Cathode

• black wire to A4A8D1 Anode

• white wire to A4A8TP2

DETAIL "B"

(PARTIAL TOP VIEW, TYPICAL)

A7A3 INSTALLED

DETAIL "A"

(PARTIAL TOP VIEW)

A7A3 SCREW LOCATION

3043641

TRANSITION

CIRCUIT

A7A3

FAN MOUNTING

SCREW

FRONT
PANEL

A

B

(SEE NOTE.)

CHASSIS GROUND CONNECTION

A4A1 ASSEMBLY

SCREW, TPTH,

8-18 X 0.625 IN.

KEPCO P/N 101-0328

TRANSITION CIRCUIT

ASSEMBLY A7A3

(SEE DETAILS "A" AND "B")

AUXILIARY

POWER SUPPLY A5

A2A5 ASSEMBLY

(SEE FIGURE 5.)

A4A3 ASSEMBLY

(SEE FIGURE 6,)

A4A8 ASSEMBLY

(SEE FIGURE 4.)

OUTPUT MODULE

(A2) FAN)

NOTE:

TO MOUNT TRANSITION
CIRCUIT ASSEMBLY A7A3

INSERT SCREW IN

VENTILATION HOLE
AS FOLLOWS:

FOR MG MODELS: USE
HOLE A (IN LINE WITH FAN
MOUNTING SCREW).
FOR GL MODELS: USE
HOLE B

(See Note)

NOTE: For flush mounting of