KEPCO RA 40 User Manual

Ra 40, Kepco, Enclosures and hardware systems

Advertising
background image

©2002, KEPCO, INC

1

Data subject to change without notice

228-0845 REV 3

I N S T R U C T I O N M A N U A L

RA 40

KEPCO

KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102

http://www.kepcopower.com " email: [email protected]

An ISO 9001 Company.

RACK SYSTEM

ENCLOSURES AND

HARDWARE SYSTEMS

DESCRIPTION. The Kepco Model RA 40 Rack Adapter is designed for the installation of Kepco Switching Power Sup-

plies into a standard 19-inch Rack. In order to accommodate the various models, mounting brackets (not supplied with

the RA 40 rack adapter) are required. The mounting brackets are first attached to the power supplies, which are then

attached to the front and rear rails of the model RA 40 Rack Adapter.

FIGURE 1. KEPCO MODEL RA 40 RACK ADAPTER SHOWN WITH POWER SUPPLIES MOUNTED

INSTALLATION The Kepco Model RA 40 Rack Adapter may be bolted permanently into a standard 19-inch rack. It can

be placed onto a rack-shelf, or it may be installed with slides. The front flanges are drilled for standard (2-1/4 inch)

mounting hole distances. The sides of the Model RA 40 Rack Adapter are drilled for “Jonathan” slides (Refer to Figure

2, Mechanical Outline Drawing).

CAUTION: Since many Kepco Switching Power Supplies are convection cooled devices, sufficient airflow

around the installed power supplies and around the rack adapter must be provided (1/4 in. mini-
mum). Ambient temperature checks on the completed installation should be compared with the
specified ambient temperature ratings of the power supplies, generally 50° C without derating, up
to 70° C with output current derating (see power supply instruction manual). Heatsink or case tem-
peratures on the installed power supplies must not exceed specified limits.

First remove the front and rear covers of the RA 40 rack adapter, then install the power supplies by using applicable

mounting bracket (Table 1). Mounting hardware and installation instructions are provided with the mounting brackets.

TABLE 1. MOUNTING BRACKETS REQUIRED TO INSTALL POWER SUPPLIES IN RACK ADAPTER

POWER SUPPLY MODELS

MOUNTING BRACKET

MODEL NO.

POWER SUPPLY MODELS

MOUNTING BRACKET

MODEL NO.

ERD (30W, 60W, 150W)

RAB 39-40ERD

RAX (50W, 100W, 175W, 300W)

RAB 39-40RAX

ERX (30W, 60W, 120W)

RAB 39-40X

RAX (1500W)

RAB 40-RCW1500

FAW (50W, 100W, 150W)

RAB 39-40FAW

RCW (350W, 750W)

RAB 39-40RCW

FCP (3W, 10W)

RAB 39-40FMP

RCW (1500W)

RAB 40-RCW1500

FMP (3W, 10W)

RAB 39-40FMP

RKW (300W)

RAB 39-40RKW3

KRW (350KV, 351KV, 352KV) *

RAB 39-40MRW

RKW (30W, 50W, 100W, 150W, 600W)

RAB 39-40RKW6

MRW (150/151KV **, 160/161KV ***, 170/171KV ***)

RAB 39-40MRW

RKW (1500W)

RAB 40-RKW1500

*

Series KRW requires case CA 29 (supplied separately) for mounting in RA 39 or RA 40 rack adapters.

** Series MRW 150/151KV requires case CA 19 (supplied separately) for mounting in RA 39 or RA 40 rack adapters.
*** Series MRW 160/161KV and MRW 170/171KV require case CA 20 (supplied separately) for mounting in RA 39 or RA 40 rack adapters.