KEPCO RKW 30W Series Operator Manual User Manual

30w series, Kepco, 30 watt single output open frame power supplies

Advertising
background image

©2010, KEPCO, INC

1

Data subject to change without notice

228-1449 REV 5

KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102

http://www.kepcopower.com email: [email protected]

I N S T R U C T I O N M A N U A L

KEPCO

An ISO 9001 Company.

RKW

30W SERIES

30 WATT SINGLE OUTPUT

OPEN FRAME POWER SUPPLIES

I — INTRODUCTION

SCOPE OF MANUAL. This instruction manual covers

the installation and operation of the Kepco RKW 30W
Series of Open Frame, RoHS (Reduction of Hazardous
Substances) compliant, switching power supplies.

DESCRIPTION. The Kepco RKW 30W Series consists of

six models of switching power supplies, with a single output
as shown in Table 1. Units may be operated with a nominal
100V a-c to 240V a-c (input voltage range 85 to 265 Va-c),
50-60 Hz

(input frequency range 47-66Hz; units operate up to

440Hz although leakage current and efficiency specifications may
not be met).

They will also operate on 110V to 370V d-c

input. The RKW 30W Series employs a MOSFET switch
flyback converter with a fixed switching frequency of
approximately 60kHz. Regulation is provided by pulse

width modulation. A thermistor prevents excessive turn-on
current surge. Overvoltage and overcurrent protection is
provided. Current limiting with automatic recovery from
short circuit is featured. Units are convection cooled L-
chassis construction. A steel cover (Model CA 33-R) is
available as an option (contact factory for derating with
cover).

Specifications and operating limits for individual RKW 30W
models are listed in Table 1. Section II describes RKW 30W
features. Section III contains specifications and operating
limits common to all RKW 30W Series Models. Section IV
describes installation and Section V describes operation.

TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RKW 30W SERIES

MODEL

RKW 3.3-7K

RKW 5-6K

RKW 12-2.5K

RKW 15-2K

RKW 24-1.3K

RKW 48-0.65K

OUTPUT VOLTS, d-c

3.3V

5V

12V

15V

24V

48V

ADJUSTMENT RANGE, Vd-c

2.85-4.0

4.0-5.8

9.6-13.2

12-16.5

19.2-26.4

38.4-52.8

OUTPUT CURRENT (AMPS)

-10 to +50 °C

7.0

6.0

2.5

2.0

1.3

(4)

0.65

CURRENT LIMIT

(1)

(AMPS)

7.9 min

6.3 min

2.6 min

2.1 min

2.1 min

0.68 min

OVP SETTING

(2)

(VOLTS)

4.2-5.2

6.0-6.9

13.7-15.7

17.0-19.0

27.0-30.5

55.0-60.0

EFFICIENCY

100 Va-c

75%

77%

81%

81%

84%

84%

200 Va-c

76%

78%

82%

83%

85%

85%

RIPPLE

AND

NOISE

(3)

(mV p-p)

Switching ripple

(typ)

80

80

100

100

100

130

spike noise

(typ)

(1)

120

120

150

150

150

200

(1)

After the cause of the overload is removed, output is automatically restored.

(2)

An overvoltage shuts down the output. Recover by recycling a-c input (60 second delay required before resetting).

(3)

Bandwidth 100 MHz. Ripple and noise will be approximately 1.5 times these values in the operating temperature range -10 ~ 0°C. The
ripple and noise values tabulated are valid when the output is derated as shown in figure 2 from 50 ~ 65°C.

(4)

Peak Current: 2.0A (useful for motor start applications).

Advertising