Q U I C K S T A R T G U I D E

KEPCO

An ISO 9001 Company.

RKW

Programmable

SINGLE OUTPUT

PROGAMMABLE POWER SUPPLIES

I — INTRODUCTION

SCOPE OF MANUAL. This Quick Start Guide covers

the installation and operation of the Kepco RKW Series of
PFC (Power Factor Corrected), RoHS (Reduction of Haz-
ardous Substances) compliant, programmable switching
power supplies. Full specifications are listed in the applica-
ble Operator’s Manual that can be downloaded from the
Kepco web site:

• 300W: www.kepcopower.com/support/

opmanls.htm#rkw300

• 600W: www.kepcopower.com/support/

opmanls.htm#rkw600

• 1500W: www.kepcopower.com/support/

opmanls.htm#rkw1500

DESCRIPTION. The Kepco RKW Programmable Series

switching power supplies come in 300W, 600W and 1500W
sizes (see Table 1). Each size has 3.3V, 5V, 12V, 15V, 24V,
28V and 48V models.

Units may be operated with a nominal 100V a-c to 240V a-
c (input voltage range 85 to 265 Va-c), 50-60 Hz (input fre-
quency range 47-66Hz). They will also operate on 110V to
370V d-c input. Overvoltage, overcurrent, overtemperature,
fan failure and power failure protections and an isolated
remote TTL ON-OFF control are provided for all models.

An LED “output voltage ON” light and an output voltage
adjust trimmer are provided.

II — INSTALLATION

MOUNTING THE POWER SUPPLY: Refer to Figure

1. The unit may be mounted on one mounting surface. Note
the restrictions for maximum penetration of mounting
screws (M4): 0.24 in (6 mm) from case. The air surrounding
the power supply must not exceed the ambient values
given in the graph in Figure 4.
CONNECTIONS: Figure 2 shows proper connection of

one or more loads using either remote or local sensing. If
local or remote sensing is not configured, the unit will
not work properly.
The unit is shipped with local sense
cables in place for Local sensing. For remote sensing,
remove the local sense cables and connect the +S and –S
terminals to the load. Remote sensing compensation is up
to 0.4V per load wire (0.15V for 3.3V models, 0.25V for 5V
models). Transient recovery specs may not be met when
remote sensing is used. If oscillations set off overvoltage
protection, install one electrolytic capacitor (470

µF min)

between +S and + and one between – and –S terminals.
The AC input power is applied via the terminal block. Make
sure to connect the AC input Neutral, Line and Ground
wires to the respective terminals of the terminal block (see
Figure 3). Sensing (either Local or Remote) MUST be
used.

TABLE 1. RKW OUTPUT RATINGS

Series

Rating

3.3V

5V

12V

15V

24V

28V

48V

RKW

300W

Model

3.3-70K

5-60K

12-27K

15-22K

24-14K

28-12K

48-7K

Output Current (Amperes d-c)

70A

60A

27A

22A

14A

12A

7A

Adjustment Range (Volts d-c)

1.8-3.6

3.5-6.0

7.2-14.4

10.5-18.0

16.8-28.8

19.6-33.6

33.6-52.8

RKW

600W

Model

3.3-150K

5-120K

12-53K

15-43K

24-27K

28-23K

48-13K

Output Current (Amperes d-c)

150A

120A

53A

43A

27A

23A

13A

Adjustment Range (Volts d-c)

1.8-3.6

3.5-6.0

7.2-14.4

10.5-18.0

16.8-28.8

19.6-33.6

33.6-52.8

RKW

1500W

Model

3.3-375K

5-300K

12-125K

15-100K

24-65K

28-55K

48-32K

Output Current (Amperes d-c)

375A

300A

125A

100A

65A

55A

32A

Adjustment Range (Volts d-c)

1.8-3.6

3.5-6.0

7.2-14.4

10.5-18.0

16.8-28.8

19.6-33.6

33.6-52.8