KEPCO RMW 300W Series Operator Manual User Manual

300w series, Kepco, 300 watt, pfc, open frame power supplies

Advertising
background image

©2012, KEPCO, INC

1

Data subject to change without notice

243-1300 REV

7

KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102

http://www.kepcopower.com email: [email protected]

I N S T R U C T I O N M A N U A L

KEPCO

An ISO 9001 Company.

RMW

300W SERIES

300 WATT, PFC,

OPEN FRAME POWER SUPPLIES

I — INTRODUCTION

SCOPE OF MANUAL. This instruction manual covers

the installation and operation of the Kepco RMW 300W
Series of RoHS-compliant Open Frame PFC (Power Factor
Corrected) Switching Power Supplies.

DESCRIPTION. Kepco RMW Series are 300W RoHS-

compliant switching power supplies with seven models pro-
viding 5V, 12V, 15V, 24V, 28V, 48V and a triple output
model (RMW 51212K-300) which provides a primary output
of +5V and secondary outputs of ±12V). All models include
1) a separate +12V output that can be used to power an
external cooling fan (not supplied), 2) a separate output
that can be used to drive a “Power OK” LED (not supplied).

Remote sensing capability (compensation 0.5V per lead)
and Power Factor Correction (PFC) is included in all mod-
els.

Units may be operated with nominal 115V a-c or 230V a-c
(input voltage range 85 to 264 Va-c), 50-60 Hz (input fre-
quency range 47-63Hz). Units operate up to 400Hz
although leakage current, power factor and efficiency spec-
ifications may not be met. They will also operate on 120V to
370V d-c input. Units are convection cooled U-chassis con-
struction.

Specifications and operating limits for individual RMW
300W models are listed in Table 1. Section II contains
specifications and operating limits common to all RMW
300W Series Models. Section III describes RMW 300W
features. Section IV describes installation and Section V
describes operation.

TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

MODEL

Nominal

Output

Voltage

Setting

Accuracy

Adjustment

Range
(V d-c)

OVP

Range

(2)

(V d-c)

Output Current

Efficiency

@115V a-c

(%)

Min.

(A d-c)

Rated

(3)

(A d-c)

Max.

(4)

(A d-c)

RMW 5-60K

+5V

±50mV

4.5-5.5

5.8-7.3

0

60

72

83

RMW 51212K-300

+5V

±50mV

(1)

4.5-5.5

5.7-7.3

0

32

45

85

(5)

+12V

±600mV

(1)

Fixed

NA

0

11

14

–12V

±600mV

(1)

Fixed

NA

0

1

2

RMW 12-25K

+12V

±100mV

10.8-13.2

14.3-18.3

0

25

30

88

RMW 15-20K

+15V

±100mV

13.5-16.5

19.1-21.6

0

20

23

86

RMW 24-12K

+24V

±100mV

21.6-26.4

28.4-33.4

0

12

14.6

88

RMW 28-11K

+28V

±100mV

25.2-30.8

33-42

0

11

12.6

88

RMW 48-6.5K

+48V

±100mV

43.2-52.8

60-67

0

6.25

7.3

90

(1)

The +5V output is preset to between 4.95V and 5.05V for 60% of rated load and nominal input line while the other outputs are verified
to be within the specified accuracy range.

(2)

An overvoltage shuts down the output. Recover by recycling a-c input.

(3)

Overcurrent protection point: 120% - 150% of rated load current, auto-recovery (except for 5V models which latch off).

(4)

Requires 18 CFM (22 CFM for 24V, 28V and 48V models) forced air cooling.

(5)

85% efficiency for all three outputs combined.

Advertising