3
INSTALLATION
24
OPTISONIC 3400
www.krohne.com
11/2013 - 4002037702 - HB OPTISONIC 3400 -en-R02
3.7 Mounting
3.7.1 Flange deviation
3.7.2 Mounting position
CAUTION!
Max. permissible deviation of pipe flange faces:
L
max
- L
min
≤ 0.5 mm / 0.02"
Figure 3-13: Flange deviation
1 L
max
2 L
min
Figure 3-14: Horizontal and vertical mounting