Page 51 | AlliedWare™ OS How To Note: EPSR

Debugging

Now that the ring is back up, the master node blocks its secondary port for the data VLAN,
transmits a Ring-Up-Flush-FDB message, flushes its FDB, sends a trap, and changes the EPSR
state to Complete.

The master node receives the Ring-Up-Flush-FDB message back on its secondary port,
because the packet traversed the whole ring. The master node ignores the message.

8. The master node returns the ring to a state of Complete

Block EPSR:test port:2 VLAN:2

EPSR Port1 Tx: 00e02b00 00040000 cd280619 8100e3e8 005caaaa 0300e02b

00bb0100 00541fea 00000000 0000cd28 0619990b 00400106 03e80000 00000000

cd280619 00000000 01000000

EPSR Port1 Tx:

-----------------------------------------------------------------------

TYPE = RING-UP-FLUSH-FDB STATE = COMPLETE

CTRL VLAN = 1000 SYSTEM = 00-00-cd-28-06-19

HELLO TIME = 0 FAIL TIME = 0

HELLO SEQ = 0

-----------------------------------------------------------------------

Flush FDB EPSR: test vid: 2

EPSR INFO: Send trap EPSR:test oldState:FAILED newState:COMPLETE

nodeType:MASTER

EPSR test oldState:FAILED newState:COMPLETE

9. The master node receives the Ring-Up-Flush-FDB message on port 2

EPSR Port2 Rx: 00e02b00 00040000 cd280619 8100e3e8 005caaaa 0300e02b

00bb0100 00541fea 00000000 0000cd28 0619990b 00400106 03e80000 00000000

cd280619 00000000 01000000

EPSR Port2 Rx:

-----------------------------------------------------------------------

TYPE = RING-UP-FLUSH-FDB STATE = COMPLETE

CTRL VLAN = 1000 SYSTEM = 00-00-cd-28-06-19

HELLO TIME = 0 FAIL TIME = 0

HELLO SEQ = 0

-----------------------------------------------------------------------