Installation – KROHNE OPTIFLEX 1100C Quickstart EN User Manual
Page 4
2
INSTALLATION
4
OPTIFLEX 1100 C
www.krohne.com
01/2012 - 4001226201 - QS OPTIFLEX 1100 R01 en
2.1 Ø2 mm / 0.08¨ single cable probe (liquid applications)
2.1.1 Scope of delivery
2.1.2 How to assemble a single cable probe
INFORMATION!
Do a check of the packing list to make sure that you have all the elements given in the order.
Figure 2-1: Scope of delivery: device with Ø2 mm single cable probe option
1 Converter, process connection and probe
2 Counterweight
3 2 HC M6×5 screws for the counterweight
4 Probe assembly cover. For more data, refer to
How to turn or remove the signal converter
on page 14.
5 Sticker: if you adjust the probe length, write the new value on the sticker
6 Quick Start
7 Strap wrench
Adjust the probe length to the tank height
Figure 2-2: How to assemble the Ø2 mm / 0.08¨ single cable probe: part 1
L = Probe length (thread stop to the bottom of the counterweight
m = Counterweight length = 100 mm / 4¨
n = Cable insertion length = 15 mm / 0.6¨