Installation, 2 recommended mounting position – KROHNE OPTIWAVE 7300C EN User Manual

Page 22

Advertising
background image

3

INSTALLATION

22

OPTIWAVE 7300 C

www.krohne.com

03/2014 - 4000172405 - HB OPTIWAVE 7300 R07 en

3.5.2 Recommended mounting position

CAUTION!
Follow these recommendations to make sure that the device measures correctly.

Figure 3-4: Recommended nozzle position for liquids, pastes and slurries

1 Nozzles for DN40 or DN50 Horn antennas, or DN50 Hygienic antenna
2 Nozzles for DN80, DN100, DN150 or DN200 Horn antennas, or DN80 or DN150 Drop antenna
3 Tank height
4 Tank diameter
5 Minimum distance of nozzle from the tank wall : 1/7 × tank height

Maximum distance of nozzle from the tank wall : 1/3 × tank diameter

6 Minimum distance of nozzle from the tank wall : 1/10 × tank height

Maximum distance of nozzle from the tank wall : 1/3 × tank diameter

INFORMATION!
If possible, do not install a nozzle on the tank centerline.

CAUTION!
Do not put the device near to the product inlet. If the product that enters the tank touches the
antenna, the device will measure incorrectly. If the product fills the tank directly below the
antenna, the device will also measure incorrectly.

Advertising