4.5.2 Thermocouple measuring inserts
Wiring of a thermocouple measuring insert is done acc. to DIN EN 60584.
TC 100: Wiring depending on sheath diameter
TC 100: Wiring
1 Single design
2 Double design
Diameter [mm] / [inches]
Single thermocouple
Double thermocouple
3 / 0.118
Type J (Fe-CuN) and
Type K (NiCr-Ni)
Type J (Fe-CuN) and
Type K (NiCr-Ni)
6 / 0.236
Type J (Fe-CuN) and
Type K (NiCr-Ni)
Type J (Fe-CuN) and
Type K (NiCr-Ni)
INFORMATION!
The TC 100 thermocouple measuring inserts are available in element types J (Fe-CuN) and
K (NiCr-Ni).
INFORMATION!
Thermocouple measuring inserts are delivered in tolerance class 1 acc. to DIN EN 60584-2.