4

ELECTRICAL CONNECTIONS

18

OPTITEMP TR/TC 100

www.krohne.com

10/2009 - 4000630002 - MA OPTITEMP TR/TC 100 R02 en

4.5.2 Thermocouple measuring inserts

Wiring of a thermocouple measuring insert is done acc. to DIN EN 60584.

TC 100: Wiring depending on sheath diameter

TC 100: Wiring

1 Single design
2 Double design

Diameter [mm] / [inches]

Single thermocouple

Double thermocouple

3 / 0.118

Type J (Fe-CuN) and

Type K (NiCr-Ni)

Type J (Fe-CuN) and

Type K (NiCr-Ni)

6 / 0.236

Type J (Fe-CuN) and

Type K (NiCr-Ni)

Type J (Fe-CuN) and

Type K (NiCr-Ni)

INFORMATION!
The TC 100 thermocouple measuring inserts are available in element types J (Fe-CuN) and
K (NiCr-Ni).

INFORMATION!
Thermocouple measuring inserts are delivered in tolerance class 1 acc. to DIN EN 60584-2.