Device description – KROHNE OPTITEMP TCA Ex EN User Manual

Page 6

Advertising
background image

2

DEVICE DESCRIPTION

6

OPTITEMP TRA/TCA

www.krohne.com

10/2010 - 4001087001 - Ex AD OPTITEMP TRA/TCA R02 en

VGC key

Designation

Variants

1

Type of thermowell tip

VGC 1 = straight tip

VGC 4 = tapered tip

2

Abbreviation for full

description of

thermometer

For VGC1: 1 = TRA-P10 (insert version); 2 = TRA-S11 (threaded version);

3 = TRA-S12 (threaded version); 4 = TRA-F13 (flange version); A = TCA-P10

(insert version); B = TCA-S11 (threaded version);

C = TCA-S12 (threaded version); D = TCA-F13 (flange version); L = TRA-

P14 (without thermowell); T = TCA-P14 (without thermowell)

For VGC4: 1 = TRA-P40 (insert version); 2 = TRA-S41 (threaded version);

3 = TRA-F42 (flange version); A = TCA-P40 (insert version); B = TCA-S41

(threaded version);C = TCA-F42 (flange version)

3

Ex-Approval

0 = without; 2 = ATEX- Ex-i

4

Type of connection

head

3 = BUZ-T; 5 = BUZ-H

5

Sensor circuit type

0 = without; 1 = 1xPt100 2-wire; 2 = 1xPt100 3-wire; 3 = 1xPt100 4-wire;

A = 1xthermocouple type J; B = 1xthermocouple type K

6

Sensor class

4 = class A, Mi, WW;, A = Class 1, thermocouple

7

Thermowell material

0 = without; 1 = 1,4571, 316Ti; 2 = 1,4841, 314

8

Not Ex-relevant

9

Insertion length

For VGC1: 0 = without; 1 = 75 mm / 2.95"; 2 = 100 mm / 3.94"; 3 = 115 mm /

4.53"; 4 = 160 mm / 6.30"; 6 = 225 mm / 8.86"; 7 = 250 mm / 9.84";

8 = 270 mm / 10.63"; A = 305 mm / 12.01"; B = 315 mm / 12.40";

C = 390 mm / 15.35"; D = 395 mm / 15.55";

E = 400 mm / 15.75"; F = 465 mm / 18.31"; G = 480 mm / 18.90";

H = 545 mm / 21.46"; K = 725 mm / 28.54"; Z = special length

For VGC4: 0 = without; 1 = 160 mm / 6.30"; 2 = 220 mm / 8.66";

3 = 225 mm / 8.86"; 4 = 280 mm / 11.02"; 5 = 285 mm / 11.22"; 6 = 307mm;

7 = 345 mm / 13.58"; 8 = 367 mm / 14.45"; A = 427 mm / 16.81"; Z = special

length

10

Length of neck pipe

For VGC1: 0 = without; 1 = 80 mm / 3.15"; 3 = 145 mm / 5.71; Z = special

length

For VGC4: 0 = without; 1 = 80 mm / 3.15"; 2 = 82 mm / 3.23"; 3 = 145 mm /

5.71; 4 = 147 mm / 5.79

11

Connection type

(head-mounted

transmitter)

0 = without; 2 = head-mounted transmitter TT10C; 7 = head-mounted

transmitter TT30C; D = head-mounted transmitter TT50C; E = head-

mounted transmitter TT51C; F = head-mounted transmitter TT60C

12

Connection type (rail-

mount transmitter)

0 = without; 6 = rail-mount transmitter TT30R; 7 = rail-mount transmitter

TT31R (1channel); 8 = rail-mount transmitter TT31R (2channel)

13

Not Ex-relevant (14th to 20th position), not used (21st to 25th position)